0

Full Content is available to subscribers

Subscribe/Learn More  >

Global Buckling Analysis of Stem Pipe During Side-Step in J-Lay Tower

[+] Author Affiliations
Bob (H. E. J.) van der Heijden, Richard Liu, Gabriel Vazquez Perez, Henk Smienk

Heerema Marine Contractors, Leiden, The Netherlands

Paper No. OMAE2015-41103, pp. V05BT04A029; 9 pages
doi:10.1115/OMAE2015-41103
From:
  • ASME 2015 34th International Conference on Ocean, Offshore and Arctic Engineering
  • Volume 5B: Pipeline and Riser Technology
  • St. John’s, Newfoundland, Canada, May 31–June 5, 2015
  • Conference Sponsors: Ocean, Offshore and Arctic Engineering Division
  • ISBN: 978-0-7918-5652-9
  • Copyright © 2015 by ASME

abstract

Within Heerema Marine Contractors’ (HMC) global installation analysis scope, the sidestep procedure of structures (e.g. in-line tee structure, 2nd end FLET structure or upper riser assembly structure) is identified that might require global buckling analysis. During a side-step procedure a structure is skidded out of the J-Lay tower while free-standing via the stem pipe on the hang off collar of the last hex-joint. While skidding the tower cannot support the structure vertically, only horizontally via a side step clamp higher up in the tower. Hence the stem pipe could buckle globally under the structure weight. The weight of the structure causes compression in the stem pipe and a center of gravity offset of the structure with respect to the pipe centerline causes a bending moment leading to potential global buckling.

A global buckling analysis must be performed to check this load case. The purpose of this paper is to provide validation for the use of Flexcom for performing global buckling analysis for the side-step procedure of structures in the J-Lay tower. In order to prove that Flexcom can indeed model global buckling behavior with sufficient accuracy, the critical buckling load obtained is validated using the FE packages Abaqus and Ansys. This comparison serves as validation, not only for the use of Flexcom, but also for the method used to determine the critical buckling load in Flexcom.

The analysis methodology used to assess a pipeline or riser for global buckling behavior is updated using the benefits of Flexcom. The use of Flexcom for global buckling analysis is more efficient, due to the ease and simplicity of modeling, and allows dynamic load cases, due to environmental loads and vessel motions, to be analyzed. Hence the potential benefit of performing global buckling analysis in Flexcom.

Copyright © 2015 by ASME
Topics: Pipes , Buckling

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In