abstract

It is important to have a quantitative method to establish a standard way to measure stability and osseointegration of implants. Among other benefits, these measurements would provide information leading to the prediction of healing time around the implant and the monitoring of the health of the implant’s interface. The dental industry has been looking for non-destructive methods to measure implant integration within the bone. In previous studies, resonance frequency analysis revealed a clear relationship between resonance frequency measurements and stiffness of the implant interface and the effective length of the implant. These studies have examined only one mode of vibration or have suffered from measurement difficulties. Furthermore, no study has evaluated the damping properties of the interface and surrounding tissues. This paper describes the development of an instrument capable of capturing and measuring information to characterize the process of dental implant osseointergration. The parameters needed to measure stability and osseointegration of implants are the stiffness of the implant components (which are a function of their geometry and material composition) and the stiffness and damping properties of the implant-bone interface and surrounding tissues. The instrument developed provides valuable information about the stiffness and damping properties of the implant-bone interface obtained through resonance frequency analysis with torsional, longitudinal and transverse vibration. Experimental, analytical, and finite element analysis results are presented.

Copyright © 2002 by ASME
Topics: Resonance , Stability , Bone

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In