Rack-Level Study of Hybrid Cooled Servers Using Warm Water Cooling With Variable Pumping for Centralized Coolant System

[+] Author Affiliations
Manasa Sahini, Chinmay Kshirsagar, Dereje Agonafer

University of Texas at Arlington, Arlington, TX

Patrick McGinn

CoolIT Systems, Calgary, AB, Canada

Paper No. IPACK2018-8255, pp. V001T02A003; 6 pages
doi:10.1115/IPACK2018-8255
From:
  • ASME 2018 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems
  • ASME 2018 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems
  • San Francisco, California, USA, August 27–30, 2018
  • Conference Sponsors: Electronic and Photonic Packaging Division
  • ISBN: 978-0-7918-5192-0
  • Copyright © 2018 by ASME

abstract

As global demand for data centers grows, so does the size and load placed on data centers, leading constraints on power and space available to the operator. Cooling power consumption is a major part of the data center energy usage. Liquid cooling technology has emerged as a viable solution in the process of optimization of the energy consumed per performance unit. In this data center rack level evaluation, 2OU (Open U) hybrid (liquid+air) cooled web servers are tested to observe the effects of warm water cooling on the server component temperatures, IT power and cooling power. The study discusses the importance of variable speed pumping in a centralized coolant configuration system.

The cooling setup includes a mini rack capable of housing up to eleven hybrid cooled web servers and two heat exchangers that exhaust the heat dissipated from the servers to the environment (the test rig data center room). The centralized configuration has two redundant pumps placed in series with heat exchanger at the rack. Each server is equipped with two passive (i.e. no active pump) cold plates for cooling the CPUs while rests of the components are air cooled. Synthetic stress load has been generated on each server using stress-testing tools. Pumps in the servers are separately powered using an external power supply. The pump speed is proportional to the voltage across the armature [1]. The pump rpm has been recorded with input voltages ranging from 11V to 17V. The servers are tested for higher inlet temperatures ranging from 25°C to 45°C which falls within the ASHRAE liquid cooled envelope W4 [2]. Variable pumping has been achieved by using different input voltages at respective inlet temperatures.

Copyright © 2018 by ASME
Topics: Cooling , Coolants , Water

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In