0

A Modular Approach for Lightweight Humanoid Hand Design Using High Torque Density Electric Actuators PUBLIC ACCESS

[+] Author Affiliations
Haotian Cui, Shuangyue Yu, Hao Su

City College of New York, New York, NY

Xunge Yan

INNFOS (Beijing) Technology Co., Ltd., Beijing, China

Shuo-Hsiu Chang, Gerard Francisco

University of Texas Health Science Center at Houston, Houston, TX

Qiushi Fu

University of Central Florida, Orlando, FL

Paper No. DMD2018-6922, pp. V001T10A012; 4 pages
doi:10.1115/DMD2018-6922
From:
  • 2018 Design of Medical Devices Conference
  • 2018 Design of Medical Devices Conference
  • Minneapolis, Minnesota, USA, April 9–12, 2018
  • ISBN: 978-0-7918-4078-8
  • Copyright © 2018 by ASME

abstract

The human hand has extraordinary dexterity with more than 20 degrees of freedom (DOF) actuated by lightweight and efficient biological actuators (i.e., muscles). The average weight of human hand is only 400g [1]. Over the last few decades, research and commercialization effort has been dedicated to the development of novel robotic hands for humanoid or prosthetic application towards dexterous and biomimetic design [2]. However, due to the limitations of existing electric motors in terms of torque density and energy efficiency, the design of humanoid hands has to compromise between dexterity and weight. For example, commercial prosthetic terminal devices i-Limb [3] and Bebionic [4] prioritize the lightweight need (450g) and use 5-DOF motors to under-actuated 11 joints, which is only able to realize a few basic grasp postures. On the other hand, some humanoid robot hand devices like DLR-HIT I & II hands [5] prioritize the dexterity need (15 DOF), but weigh more than four times than their biological counterpart (2200g and 1500g, respectively).

Copyright © 2018 by ASME
Topics: Density , Torque , Actuators , Design
This article is only available in the PDF format.

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In