0

Full Content is available to subscribers

Subscribe/Learn More  >

Effect of Micro-Grooving on the Stress Shielding of Titanium: Experimental and Numerical Investigations

[+] Author Affiliations
Harsha G. Jamadagni, Lokesh Dhanasekaran, M. Khandaker

University of Central Oklahoma, Edmond, OK

Hasan Karaman, Fatih Karpat

Uludağ University, Bursa, Turkey

Wendy Williams

University of Oklahoma Health Sciences Center, Oklahoma City, OK

Paper No. IMECE2017-70946, pp. V003T04A021; 5 pages
doi:10.1115/IMECE2017-70946
From:
  • ASME 2017 International Mechanical Engineering Congress and Exposition
  • Volume 3: Biomedical and Biotechnology Engineering
  • Tampa, Florida, USA, November 3–9, 2017
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-5836-3
  • Copyright © 2017 by ASME

abstract

Micron sizes grooves can control the cell settlement on the implant surface or be used to direct tissue generation at the implant/bone interface. The effect of shape, size and the type of material of the microgrooves on the mechanical stimulus transfer from the implant to bone at physiological loading is not known yet. Therefore, this study evaluated both experimentally and numerically the effect of surface modification on a titanium implant to the load transfer characteristics from implant to bone for examining stress shielding parameters. This study measured the effect of micron grooves on titanium to the mechanical stability of titanium using a rabbit model. This study also developed a finite element model based on the in vivo test model to examine the stress shielding parameters. The results showed that the mean values of fracture strength were significantly higher for grooved titanium samples (1.32±0.45 MPa, n = 3) compared to control samples (without any groove) (0.22±0.16 MPa, n = 6) (P < 0.05). The load-displacement graph from the pull out tension tests was used to measure the frictional coefficient between Ti and bone from the FEA model. It was found from the FEA model that the average co-efficient of friction between titanium and bone was 0.50. Maximum equivalent stress along the interface of microgrooves on titanium was higher from groove area in compare to the non-groove area because of the change of the geometry along the groove. The microgrooves in the model have a significant effect on the stress transfer parameter between implant and adjoining bone. The unequal load sharing due to micro-grooving causes an increase in stiffness of the adjacent bone to the implant.

Copyright © 2017 by ASME
Topics: Stress , Titanium

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In