0

Full Content is available to subscribers

Subscribe/Learn More  >

Design and Evaluation of Advanced Smart Needles for Brain Biopsy

[+] Author Affiliations
Mohammad Sahlabadi, Seyedvahid Khodaei, Parsaoran Hutapea

Temple University, Philadelphia, PA

Paper No. SMASIS2017-3838, pp. V002T04A015; 4 pages
doi:10.1115/SMASIS2017-3838
From:
  • ASME 2017 Conference on Smart Materials, Adaptive Structures and Intelligent Systems
  • Volume 2: Modeling, Simulation and Control of Adaptive Systems; Integrated System Design and Implementation; Structural Health Monitoring
  • Snowbird, Utah, USA, September 18–20, 2017
  • Conference Sponsors: Aerospace Division
  • ISBN: 978-0-7918-5826-4
  • Copyright © 2017 by ASME

abstract

Biopsy involves removing a piece of tissues for further medical examination. Brain biopsy is generally performed using different techniques, such as open biopsy, stereotactic core biopsy, and needle biopsy. Open biopsy is the most common and the most invasive form of the brain biopsy. During the procedure, a piece of the skull is removed and the brain is exposed. Stereotactic core and needle biopsies are minimally invasive. In these procedures, a hole is usually drilled into the skull and a needle is inserted through the hole to extract the tissue. Brain biopsy has its risks and complications due to the vulnerability of the brain tissue. Although using needle or stereotactic biopsies reduce the risks, brain biopsy may cause swelling or bleeding in the brain, and in some cases, can result in infection, stroke, seizure or even coma. A needle biopsy with conventional needles involves pulling or pushing the cutting stylet inside the needle hollow body (cannula). The manual pulling and pushing procedure induces lateral movement of the needle, which increases the damage in brain tissue. The goal here is to completely remove the needle harmful lateral movement. In this work, design of smart biopsy needles is proposed and demonstrated by incorporating nitinol wires and springs to control the lateral movement of the cutting stylet. The first design comprises of two parts. The first part of the needle is a 360° tissue cutting stylet, and the second part is the cannula. The cutting stylet can slide inside the cannula and a nitinol wire is embedded at the end of the stylet and the end of the cannula. As the electric current is applied on the nitinol wire, it shrinks and pulls the cutting stylet. The second design is almost similar to the first design, but it has a 180° tissue cutting stylet with a similar actuating mechanism. The last design uses a nitinol torsion spring that is attached to the cutting stylet. It cuts tissue samples by activating the nitinol spring to rotate the cutting stylet.

Copyright © 2017 by ASME
Topics: Design , Brain , needles

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In