Experimentally Validated Computational Fluid Dynamics Model for Data Center With Active Tiles

[+] Author Affiliations
Jayati D. Athavale, Yogendra Joshi, Minami Yoda

Georgia Institute of Technology, Atlanta, GA

Paper No. IPACK2017-74108, pp. V001T02A006; 13 pages
doi:10.1115/IPACK2017-74108
From:
  • ASME 2017 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems collocated with the ASME 2017 Conference on Information Storage and Processing Systems
  • ASME 2017 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems
  • San Francisco, California, USA, August 29–September 1, 2017
  • Conference Sponsors: Electronic and Photonic Packaging Division
  • ISBN: 978-0-7918-5809-7
  • Copyright © 2017 by ASME

abstract

This paper presents an experimentally validated room-level computational fluid dynamics (CFD) model for raised-floor data center configurations employing active tiles. Active tiles are perforated floor tiles with integrated fans, which increase the local volume flowrate by redistributing the cold air supplied by the computer room air conditioning (CRAC) unit to the under-floor plenum. In a previous study [1], experiments were conducted to explore the potential of active tiles for economically and efficiently eliminating hot spots in data center. Our results indicated that active tiles, as the actuators closest to the racks, can significantly and quickly impact the local distribution of cooling resources. They could therefore be used in an appropriate control framework to rapidly mitigate hot spots, and maintain local conditions in an energy-efficient manner.

The numerical model of the data center room operates in an under-floor supply and ceiling return cooling configuration and consists of one cold aisle with 12 racks arranged on both sides and three CRAC units sited around the periphery of the room. The commercial computational fluid dynamics (CFD) software package Future Facilities 6SigmaDCX [2], which is specifically designed for data center simulation, is used to develop the model. First, a baseline model using only passive tiles was developed and experimental data were used to verify and calibrate plenum leakage for the room. Then a CFD model incorporating active tiles was developed for two configurations: (a) a single active tile and 9 passive tiles in the cold aisle; and (b) an aisle populated with 10 (i.e., all) active tiles. The active tiles are modeled as a combination of a grill, fan elements and flow blockages to closely mimic the actual active tile used in the experimental studies. The fan curve for the active tile fans is included in the model to account for changes in flow rate through the tiles in response to changes in plenum pressure.

The model with active tiles is validated by comparing the flow rate through the floor tiles, relative plenum pressure and rack inlet temperatures for selected racks with the experimental measurements. The predictions from the CFD model are found to be in good agreement with the experimental data, with an average discrepancy between the measured and computed values for total flow rate and rack inlet temperature less than 4% and 1.7 °C, respectively. These validated models were then used to simulate steady state and transient scenarios following cooling failure.

This physics-based and experimentally validated room-level model can be used to predict temperature and flow distributions in a data center using active tiles. These predictions can then be used to identify the optimal number and locations of active tiles to mitigate hot spots, without adversely affecting other parts of the data center.

Copyright © 2017 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In