0

Full Content is available to subscribers

Subscribe/Learn More  >

Two-Phase Mini-Thermosyphon for Cooling of Datacenters: Experiments, Modeling and Simulations

[+] Author Affiliations
Chin L. Ong, Raffaele L. Amalfi, Jackson B. Marcinichen, Nicolas Lamaison, John R. Thome

EPFL-STI-IGM-LTCM, Lausanne, Switzerland

Paper No. IPACK2017-74030, pp. V001T02A003; 12 pages
doi:10.1115/IPACK2017-74030
From:
  • ASME 2017 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems collocated with the ASME 2017 Conference on Information Storage and Processing Systems
  • ASME 2017 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems
  • San Francisco, California, USA, August 29–September 1, 2017
  • Conference Sponsors: Electronic and Photonic Packaging Division
  • ISBN: 978-0-7918-5809-7
  • Copyright © 2017 by ASME

abstract

Nowadays, datacenters heat density dissipation follows an exponential increasing trend that is reaching the heat removal limits of the traditional air-cooling technology. Two-phase cooling implemented within a gravity-driven system represents a scalable and viable long-term solution for datacenter cooling in order to increase the heat density dissipation with larger energy efficiency and lower acoustic noise. The present article builds upon the 4-part set of papers presented at ITHERM 2016 for a 15-cm height thermosyphon to cool a contemporary datacenter cabinet, providing new test data over a wider range of heat fluxes and new validations of the thermal-hydrodynamics of our thermosyphon simulation code.

The thermosyphon consists of a microchannel evaporator connected via a riser and a downcomer to a liquid-cooled condenser for the cooling of a pseudo-chip to emulate an actual server. Test results demonstrated good thermal performance coupled with uniform flow distribution for the new larger range of operating test conditions. At the maximum imposed heat load of 158 W (corresponding to a heat flux of 70 W cm−2) with a water inlet coolant at 20 °C, water mass flow rate of 12 kg h−1 and thermosyphon filling ratio of 78%, the pseudo mean chip temperature was found to be 58 °C and is well below the normal thermal limits in datacenter cooling.

Finally, the in-house LTCM’s thermosyphon simulation code was validated against an expanded experimental database of about 262 data points, demonstrating very good agreement; in fact, the pseudo mean chip temperature was predicted with an error band of about 1 K.

Copyright © 2017 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In