0

Full Content is available to subscribers

Subscribe/Learn More  >

Impulsively-Generated Pressure Transients and Strains in a Cylindrical Fluid-Filled Tube Terminated by a Converging Section

[+] Author Affiliations
Jean-Christophe Veilleux, Joseph E. Shepherd

California Institute of Technology, Pasadena, CA

Paper No. PVP2017-65471, pp. V004T04A005; 10 pages
doi:10.1115/PVP2017-65471
From:
  • ASME 2017 Pressure Vessels and Piping Conference
  • Volume 4: Fluid-Structure Interaction
  • Waikoloa, Hawaii, USA, July 16–20, 2017
  • Conference Sponsors: Pressure Vessels and Piping Division
  • ISBN: 978-0-7918-5797-7
  • Copyright © 2017 by ASME

abstract

The syringe in a subcutaneous autoinjector may be subjected to internal pressure transients due to the normal operation of the injection mechanism. These transients are similar to transients in fluid-filled pipelines observed during water hammer events. In this paper, the effect of an air gap in the syringe and a converging section are studied experimentally and numerically in a model system which consists of a fluid-filled metal tube that is impulsively loaded with a projectile to simulate the action of the autoinjector mechanism operation.

The air between the buffer and the water results in a complex interaction between the projectile and the buffer. Also, there are tension waves inside the tube due to the presence of a free surface, and this causes distributed cavitation which, in turn, gives rise to steepening of the pressure waves. The converging section can amplify the pressure waves if the wave front is sharp. Pressures as high as 50 MPa have been measured at the apex of the cone with impact velocities of 5.5 m/s.

Copyright © 2017 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In