Experimental Investigation of an Ammonia-Water Diffusion-Absorption Refrigerator (DAR) at Part Load

[+] Author Affiliations
Ahmad Najjaran Kheirabadi, James Freeman, Alba Ramos Cabal, Christos N. Markides

Imperial College London, London, UK

Paper No. HT2017-4830, pp. V001T09A004; 7 pages
doi:10.1115/HT2017-4830
From:
  • ASME 2017 Heat Transfer Summer Conference
  • Volume 1: Aerospace Heat Transfer; Computational Heat Transfer; Education; Environmental Heat Transfer; Fire and Combustion Systems; Gas Turbine Heat Transfer; Heat Transfer in Electronic Equipment; Heat Transfer in Energy Systems
  • Bellevue, Washington, USA, July 9–12, 2017
  • Conference Sponsors: Heat Transfer Division
  • ISBN: 978-0-7918-5788-5
  • Copyright © 2017 by ASME

abstract

Diffusion absorption refrigeration (DAR) cycles enable passive fully thermally-driven refrigeration for off-grid purposes. Typically, DAR units are designed for a given heat supply load and temperature, although real operation inevitably involves unsteady variations in these inputs. In this study, a thermally-driven DAR unit with a nominal cooling capacity of 120 W is connected to an electric heat source. The working fluid is ammonia-water NH3/H2O, with hydrogen (H2) added as an auxiliary gas to keep the system pressure constant and to decrease the partial pressure of the refrigerant (ammonia) in the evaporator. A control unit is used to adjust and measure the input heat-source power applied to the unit. The operating pressure of the system is 20.7 bar, the ambient temperature is 22 °C and the input thermal power is in the range 250 to 700 W. The cooling capacity of the unit and the input heat load are measured simultaneously at different operation conditions. To measure the cooling power, a cold box is constructed around the evaporator, and a second heater is located inside the cold box which sets the cold space temperature equal to that of the ambient. This allows the coefficient of performance (COP) to be evaluated. The COP and cooling capacity of the unit are investigated at part load by varying the heat supply, from which maximum values are obtained (0.28 and 110 W, respectively). Finally, experimental results are compared to the theoretical predictions from a thermodynamic model of a DAR cycle. Once validated, the model is also used to find the properties of the fluid mixture in different states in the DAR cycle.

Copyright © 2017 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In