Enhancing the Performance of the Building’s Vapor Compression Air Cooling System Using Earth-Air Heat Exchanger

[+] Author Affiliations
Fadi A. Ghaith

Heriot Watt University, Dubai Campus, Dubai, UAE

Fadi J. Alsouda

S.K.M. Air Conditioning Equipment Factory, Sharjah, UAE

Paper No. ES2017-3200, pp. V001T09A003; 8 pages
doi:10.1115/ES2017-3200
From:
  • ASME 2017 11th International Conference on Energy Sustainability collocated with the ASME 2017 Power Conference Joint With ICOPE-17, the ASME 2017 15th International Conference on Fuel Cell Science, Engineering and Technology, and the ASME 2017 Nuclear Forum
  • ASME 2017 11th International Conference on Energy Sustainability
  • Charlotte, North Carolina, USA, June 26–30, 2017
  • Conference Sponsors: Advanced Energy Systems Division, Solar Energy Division
  • ISBN: 978-0-7918-5759-5
  • Copyright © 2017 by ASME

abstract

This paper aims to evaluate the thermal performance and feasibility of integrating the Earth-Air Heat Exchanger (EAHE) with the building’s vapor compression air cooling system. In the proposed system, the ambient air is forced by an axial fan through an EAHE buried at a certain depth below the ground surface. EAHE uses the subsoil low temperature and soil thermal properties to reduce the air temperature. The outlet air from the EAHE was used for the purpose of cooling the condenser of the vapor compression cycle (VCC) to enhance its coefficient of performance (COP). The potential enhancement on the COP was investigated for two different refrigerants (i.e. R-22 and R410a) cooling systems. A mathematical model was developed to estimate the underground soil temperature at different depths and the corresponding outlet air temperature of EAHE was calculated. The obtained results showed that the soil temperature in Dubai at 4 meters depth is about 27°C and remains relatively constant across the year. In order to estimate the effect of using EAHE on the performance of the VCC system, a sample villa project was selected as a case study. The obtained results showed that EAHE system contributed efficiently to the COP of the VCC with an overall increase of 47 % and 49 % for R-22 and R410a cycles, respectively. Moreover, the calculated values were validated against Cycle_D simulation model and showed good agreement with a maximum deviation of 5%. The payback period for this project was found to be around two years while the expected life time is about 10 years which makes it an attractive investment.

Copyright © 2017 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In