0

Full Content is available to subscribers

Subscribe/Learn More  >

Development of the Working Fluid With Blood Viscosity for Evaluating Ablation Catheter in In Vitro System

[+] Author Affiliations
Kaihong Yu, Ren Takahashi, Makoto Ohta

Tohoku University, Sendai, Japan

Paper No. IMECE2016-65975, pp. V003T04A011; 7 pages
doi:10.1115/IMECE2016-65975
From:
  • ASME 2016 International Mechanical Engineering Congress and Exposition
  • Volume 3: Biomedical and Biotechnology Engineering
  • Phoenix, Arizona, USA, November 11–17, 2016
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-5053-4
  • Copyright © 2016 by ASME

abstract

The purpose of this study was to develop a working fluid with the proper viscosity to mimic blood flow to evaluate an ablation catheter. We proposed a working fluid that matches the blood viscosity, using glycerol-saline solution or xanthan gum (XG)-saline solution. We compared the two solution mixtures at various concentrations (for glycerol-saline solution, 10%, 30%, and 50%; for XG-saline solution, 0.10%, 0.11%, 0.12%, and 0.13%) by measuring their temperature dependence on viscosity. To test the developed working fluids, RF ablations were performed with both solutions, and the flow around the catheter during ablation was observed by particle image velocimetry (PIV) method. In addition, to test the efficacy of the solution mixtures, myocardium was observed after it was soaked separately in the two solution mixtures. The viscosity of both kinds of solution mixtures increased at higher concentrations and decreased with increasing temperatures. At 37°C, the viscosities of 50% glycerol-saline solution and 0.11%–0.13% XG-saline solution were 3–4 mPa·s, a value that is similar to the viscosity of blood. The upward flow resulting from heat convection by ablation was observed around the catheter in the PIV analysis using an in vitro model without flow. The solution mixture with the higher viscosity flowed at a lower velocity around the catheter, and the myocardium soaked in 50% glycerol-saline solution shrunk into a black and tough tissue. On the other hand, the myocardium soaked in XG-saline solution showed no change in color or shape. In conclusion, the XG-saline solution is a superior option for evaluating ablation catheters.

Copyright © 2016 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In