0

Full Content is available to subscribers

Subscribe/Learn More  >

Reducing Wear Debris and Increasing Lower-Limb Amputees’ Comfort by Optimizing Prosthetic Socket Design Using Local Contact Pressure Relief and Implementing Appropriate Holes

[+] Author Affiliations
Gabi Nehme, Micheline Dib

University of Balamand, El-koura, Lebanon

Paper No. IMECE2016-65209, pp. V003T04A002; 9 pages
doi:10.1115/IMECE2016-65209
From:
  • ASME 2016 International Mechanical Engineering Congress and Exposition
  • Volume 3: Biomedical and Biotechnology Engineering
  • Phoenix, Arizona, USA, November 11–17, 2016
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-5053-4
  • Copyright © 2016 by ASME

abstract

Maintaining a comfortable fit in prosthetic socket for trans-tibial amputees (TTA) using design of experiment (DOE) and finite element model (FEM) to implement relief areas and holes in socket structure are important goals to help ensure better pressure distributions and successful rehabilitation. Design and fit of socket rely on patient acceptance and comfort. Sixteen sockets designed with different levels of reliefs and holes were investigated by Finite Element Model (FEM) and Design of Experiment (DOE) for flexibility and pressure distribution using ultra high molecular weight polyethylene (UHMWPE) and polyamide 6 (PA6) or Duraform then compared to conventional socket without any compliance.

The purpose of this study was to assess performance of sockets with compliant features integrated into the socket wall to relieve in-socket pressure, increase flexibility and patient comfort during transtibial amputee gait. Reducing thickness at designated areas and hole implementation between the Patellar Tendon (PT) and Distal Tibia (DT) would decrease stiffness and increase prosthesis range of motion where flexibility is needed without compromising mechanical efficiency and the structural integrity of the socket. Different materials sockets 3 of each obtained by FEM/DOE analysis were manufactured and used by six amputees of the same age groups to measure the level of comfort and check the worn surfaces using scanning electron microscopy (SEM) and amputee performances after one year of usage. SEM and optical images were compared. The calculated stiffness of the two compliant sockets with holes are much less than the conventional sockets; they were more comfortable and showed significant decrease in wear debris over the course of the trial period.

Copyright © 2016 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In