0

Full Content is available to subscribers

Subscribe/Learn More  >

Development of Autonomous Robotic Cataract Surgery Device

[+] Author Affiliations
Matthew Francom, Clinton Burns, Philip Repisky, Benjamin Medina, Alex Kinney, Erick Tello, Pinhas Ben-Tzvi

Virginia Tech, Blacksburg, VA

Paper No. DETC2016-59643, pp. V05AT07A066; 6 pages
doi:10.1115/DETC2016-59643
From:
  • ASME 2016 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
  • Volume 5A: 40th Mechanisms and Robotics Conference
  • Charlotte, North Carolina, USA, August 21–24, 2016
  • Conference Sponsors: Design Engineering Division, Computers and Information in Engineering Division
  • ISBN: 978-0-7918-5015-2
  • Copyright © 2016 by ASME

abstract

The current rate of incidence of cataracts is increasing faster than treatment capacity, and an autonomous robotic system is proposed to mitigate this by carrying out cataract surgeries. The robot is composed of a three actuator RPS parallel mechanism in series with an actuated rail mounted roller that moves around the eye, and is designed to perform a simplified version of the extracapsular cataract surgery procedure autonomously. The majority of the design work has been completed, and it is projected that the system will have a tool accuracy of 0.167 mm, 0.141 mm, and 0.290 mm in the x, y, and z directions, respectively. Such accuracies are within the acceptable errors of 1.77mm in the x and y directions of the horizontal plane, as well as 1.139 mm in the vertical z direction. Tracking of the tool when moving at 2 mm/s should give increments of 0.08 mm per frame, ensuring constant visual feedback. Future work will involve completing construction and testing of the device, as well as adding the capability to perform a more comprehensive surgical procedure if time allows.

Copyright © 2016 by ASME
Topics: Robotics , Surgery

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In