abstract

Sodium-cooled Fast Reactors (SFRs) have components with thinner walls as compared with light water reactors, although Japan is an earthquake-prone country. Thus, seismic isolation systems have been conventionally employed in SFR system design to reduce seismic forces on the systems in Japan.

Implementation of seismic design in the reactor core and buckling design in the reactor vessel requires 8 Hz (or less) vertical frequency’s isolation system being applied. This paper introduces three isolation concepts to achieve the frequency.

The isolation systems, which enable vertical 8 Hz natural frequency, comprise thicker laminated rubber bearings (TRBs). By combining coned disk springs with TRBs, vertical natural frequency is in a range from roughly 3 Hz to 5 Hz. Combining pneumatic springs to RBs and adding the rocking suppression system, vertical natural frequency becomes under 1 Hz. All isolation systems need horizontal damping like oil dampers.

A vertical 8 Hz isolation system with TRBs and oil dampers is under development in Japan as a principal isolation concept. This system was selected because of its simple configuration and fewer issues to be resolved in the development. Since TRBs and oil dampers are basic isolation elements, they can be applied to other isolation systems.

The response acceleration of 5 Hz vertical isolation is 50% of that of 8 Hz based on the analytical survey. A series of static tests of coned disk springs was carried out to confirm design equations. Based on these knowledge, 5 Hz vertical isolation system with TRBs and the coned disk springs can be designed.

The response acceleration of 1 Hz vertical isolation is 10% of that of 8 Hz. A rocking suppression system was studied in the past, and the further simplification of this system is the largest challenge for this concept.

These three isolation concepts are isolation candidates for SFRs in Japan. To obtain enough seismic margins for each plant site, these isolation systems need to be developed.

Copyright © 2016 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In