0

Full Content is available to subscribers

Subscribe/Learn More  >

Deterministic and Probabilistic PTS Study for a Reactor Pressure Vessel Considering Plume Cooling Effects

[+] Author Affiliations
Guian Qian, Markus Niffenegger, Medhat Sharabi, Nathan Lafferty

Paul Scherrer Institute, Villigen, Switzerland

Paper No. PVP2016-63869, pp. V06AT06A040; 12 pages
doi:10.1115/PVP2016-63869
From:
  • ASME 2016 Pressure Vessels and Piping Conference
  • Volume 6A: Materials and Fabrication
  • Vancouver, British Columbia, Canada, July 17–21, 2016
  • Conference Sponsors: Pressure Vessels and Piping Division
  • ISBN: 978-0-7918-5042-8
  • Copyright © 2016 by ASME

abstract

A reactor pressure vessel (RPV) is assumed to be subjected to pressurized thermal shocks (PTSs) as a result of the emergency cooling water injected during a loss-of-coolant accident (LOCA). The cooling flow is not homogeneous but typically in a plume shape (stripe cooling) flowing from the cold leg through the inlet nozzles. This paper aims to analyze the non-uniform cooling effect on the RPV integrity.

In this paper, both deterministic and probabilistic methods are used to analyze the integrity of a model RPV subjected to PTS. RELAP5, GRS-MIX, CFD and other semi-analytical methods are used to analyze the transient with and without considering plume cooling effect. Finite element method (FEM), extended finite element method (XFEM) and weight function method are used to calculate KI of the postulated cracks. The FAVOR code is used to calculate the conditional probabilities for crack initiation and failure of the RPV considering different crack distributions.

KI based on CFD input is the highest, followed by that based on reference transient, GRS-MIX and RELAP5. Peak KI of the cracks inside the plume increases about 33% compared with that outside. According to the maximum criteria, the maximum allowed RTNDT are 56.9 °C, 90.2 °C, 98 °C, 115.7 °C and 136.2 °C for the crack in the nozzle region based on CFD transient, the cracks in the ring region based on the CFD, reference data, GRS-MIX and RELAP5 calculated transient, respectively. These values are 36 °C, 68.5 °C, 73 °C, 81 °C and 104 °C according to the tangent criteria. The conditional probability inside the plume is more than nine orders of magnitude higher than outside the plume. Considering plume cooling effects increases the total failure frequency by 1–2 orders of magnitude. In order to be conservative, it is necessary to consider the plume effect in the integrity assessment.

Copyright © 2016 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In