0

Full Content is available to subscribers

Subscribe/Learn More  >

Evaluating a NiTi Implant Under Realistic Loads: A Simulation Study

[+] Author Affiliations
Amirhesam Amerinatanzi, Narges Shayesteh Moghaddam, Hamdy Ibrahim, Mohammad Elahinia

University of Toledo, Toledo, OH

Paper No. SMASIS2016-9287, pp. V002T03A030; 7 pages
doi:10.1115/SMASIS2016-9287
From:
  • ASME 2016 Conference on Smart Materials, Adaptive Structures and Intelligent Systems
  • Volume 2: Modeling, Simulation and Control; Bio-Inspired Smart Materials and Systems; Energy Harvesting
  • Stowe, Vermont, USA, September 28–30, 2016
  • Conference Sponsors: Aerospace Division
  • ISBN: 978-0-7918-5049-7
  • Copyright © 2016 by ASME

abstract

Additive manufacturing (i.e. 3D printing) has only recently be shown as a well-established technology to create complex shapes and porous structures from different biocompatible metal powder such as titanium, nitinol, and stainless steel alloys. This allows for manufacturing bone fixation hardware with patient-specific geometry and properties (e.g. density and mechanical properties) directly from CAD files. Superelastic NiTi is one of the most biocompatible alloys with high shock absorption and biomimetic hysteresis behavior. More importantly, NiTi has the lowest stiffness (36–68 GPa) among all biocompatible alloys [1]. The stiffness of NiTi can further be reduced, to the level of the cortical bone (10–31.2 GPa), by introducing engineered porosity using additive manufacturing [2–4]. The low level of fixation stiffness allows for bone to receive a stress profile close to that of healthy bone during the healing period. This enhances the bone remodeling process (Wolf’s Law) which primarily driven by the pattern of stress. Also, this match in the stiffness of bone and fixation mitigates the problem of stress shielding and detrimental stress concentrations.

Stress shielding is a known problem for the currently in-use Ti-6Al-4V fixation hardware. The high stiffness of Ti-6Al-4V (112 GPa) compared to bone results in the absence of mechanical loading on the adjacent bone that causes loss of bone mass and density and subsequently bone/implant failure. We have proposed additively manufactured porous NiTi fixation hardware with a patient-specific stiffness to be used for the mandibular reconstructive surgery (MRS). In MRS, the use of metallic fixation hardware and double barrel fibula graft is the standard methodology to restore the mandible functionality and aesthetic.

A validated finite element model was developed from a dried cadaveric mandible using CT scan data. The model simulated a patient’s mandible after mandibular reconstructive surgery to compare the performance of the conventional Ti-6Al-4V fixation hardware with the proposed one (porous superelastic NiTi fixation plates). An optimized level of porosity was determined to match the NiTi equivalent stiffness to that of a resected bone, then it was imposed to the simulated fixation plates. Moreover, the material property of superelastic NiTi was simulated by using a validated customized code. The code was calibrated by using DSC analysis and mechanical tests on several prepared bulk samples of Ni-rich NiTi. The model was run under common activities such as chewing by considering different levels of the applied fastening torques on screws.

The results show a higher level of stress distribution on mandible cortical bone in the case of using NiTi fixation plates. Based on wolf’s law it can lead to a lower level of stress shielding on the grafted bone and over time bone can remodel itself. Moreover, the results suggest an optimum fastening torque for fastening the screws for the superelastic fixations causes more normal distribution of stress on the bone similar to that for the healthy mandible. Finally, we successfully fabricated the stiffness-matched porous NiTi fixation plates using selective laser melting technique, and they were mounted on the dried cadaveric mandible used to create the finite element model.

Copyright © 2016 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In