In-Line inspection tools (ILI) including Magnetic Flux Leakage (MFL) and Ultrasonic (UT) technologies are commonly used to detect/measure potential anomalies in oil and gas pipelines. Some of ILI reported anomalies are usually selected for excavation and validated through field non-destructive examination techniques (NDE). It is a fact that both ILI and NDE readings are contaminated with measurement errors. Such errors are usually originated from inherent tool limitations and capabilities, measurement techniques, and/or human factors. The intend of this paper is to calibrate the corrosion ILI data relative to NDE measurement given estimated statistical errors from both tools. Commonly, a graphical representation is used to compare ILI versus field measurements; namely, a unity plot. Herein, a linear relationship between ILI and NDE measurements is assumed. Such an assumption leads to another assumption of having a linear relationship between the ILI measurement and true value. Similarly, NDE measurement has the same relationship with the true value. An advanced statistical approach based on linear regression and maximum likelihood is used to determine the uncertainty of both ILI and NDE measurement errors. This method is based on first quantifying the uncertainty of ILI and field measurement and then calibrating the ILI data relative to the field using the estimated tools errors. The tool error estimation is based on reducing the relative error between ILI and field measurements. The calibration methodology implements advanced statistics to improve both accuracy and precision of measurement data. The proposed process is validated through results from successive ILI programs. The proposed calibration can be easily adopted in ubiquitous computing spreadsheet environment and be applied to both corrosion and crack measurements.

Copyright © 2016 by ASME
Topics: Calibration

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In