0

Full Content is available to subscribers

Subscribe/Learn More  >

Tracheal Stenosis: A CFD Approach for Evaluation of Drug Delivery

[+] Author Affiliations
Shahab Taherian, Hamid Rahai, Bernardo Z. Gomez, Jeremy R. Bonifacio

California State University Long Beach, Long Beach, CA

Thomas Waddington

Long Beach Veterans Hospital, Long Beach, CA

Paper No. IMECE2015-50799, pp. V003T03A096; 9 pages
doi:10.1115/IMECE2015-50799
From:
  • ASME 2015 International Mechanical Engineering Congress and Exposition
  • Volume 3: Biomedical and Biotechnology Engineering
  • Houston, Texas, USA, November 13–19, 2015
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-5738-0
  • Copyright © 2015 by ASME

abstract

The existence of obstructions such as tracheal stenosis has major impacts on respiratory functions. Therapeutic effectiveness of inhaled medications is influenced by tracheal stenosis, and particle transport and deposition pattern are modified. The majority of studies have focused on obstructions in branches of the airways, where the flow is diverted to the other branches to meet the needed oxygen intake. In this study we have investigated the effects of trachea with and without stenosis/obstruction on particle depositions and air flow in a human respiratory system. Patient specific CFD simulations were conducted; CT-scans of a patient with tracheal stenosis were used to create 3D models of bronchial tree up to 8 generations. The section of the stenosis was manually modified to create a healthy trachea. Comparisons between CFD simulations before and after intervention demonstrate the impact of the stenosis on flow characteristics and particles distribution. The numerical investigations were performed using the implicit Unsteady Reynolds-Averaged Navier-Stokes equation (U-RANS), using the commercially available software (STAR-CCM+) from CD-Adapco, along with K-ω; shear stress transport model. Two sets of CT-images of inhalation and exhalation were used for assigning Patient-specific boundary conditions at the outlets. Lagrangian Phase model was used to simulate particle transport and depositions of 10, 5 and 2.5 micron diameter particles. Results of the particle depositions for 10 micron particles highlight the difference in depositions and ultimately inhaled medications in patients with and without tracheal stenosis. Particle deposition for normal Tidal volume increased due to stenosis from 47% to 51% for 10 Micron particles and not a significant change for the 2.5 Micron particles (from 4.5% to 4.7%).

Comparisons of pressure drop in each generation between patient with tracheal stenosis and the healthy lung showed significant increase in pressure drop after the stenosis, which were experienced in all generations downstream. Experimental validation of the CFD results were made with a model of healthy trachea up to 3rd generation, manufactured using Additive Layer Manufacturing (ALM) from CT-images and pressure results were compared with the corresponding CFD results. Good agreements were found.

Copyright © 2015 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In