0

Full Content is available to subscribers

Subscribe/Learn More  >

Soft Pressure Sensing Sleeve for Direct Cardiac Compression Device

[+] Author Affiliations
Markus A. Horvath

Technische Universität München, Munich, GermanyHarvard University, Cambridge, MA

Ellen T. Roche, Daniel M. Vogt, David J. Mooney, Conor J. Walsh

Harvard University, Cambridge, MA

Frank A. Pigula

Children’s Hospital Boston, Boston, MA

Paper No. DETC2015-47567, pp. V003T14A011; 9 pages
doi:10.1115/DETC2015-47567
From:
  • ASME 2015 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
  • Volume 3: 17th International Conference on Advanced Vehicle Technologies; 12th International Conference on Design Education; 8th Frontiers in Biomedical Devices
  • Boston, Massachusetts, USA, August 2–5, 2015
  • Conference Sponsors: Design Engineering Division, Computers and Information in Engineering Division
  • ISBN: 978-0-7918-5710-6
  • Copyright © 2015 by ASME

abstract

A direct cardiac compression (DCC) device is a non-blood contacting sleeve placed around the failing heart to actively assist blood pumping function. For design optimization of a DCC device, it is necessary to monitor the surface pressure exerted on the heart surface at multiple points during active assist, and to correlate this with device performance and cardiac output. In this paper, we present the design, fabrication and characterization of a soft, elastic, conformable pressure sensing sleeve that is placed at the heart/device interface to monitor device performance without affecting device function. This sleeve enables identification of optimal pre-tensioning, positioning and user-controlled parameters of the DCC device. Individual sensors (8×8×3 mm) were fabricated using a surface mount device (SMD) barometer on a custom double-sided flexible printed circuit board and casting the assembly in urethane rubber. A typical sensor has a dynamic range of 2.5 kPa to 50 kPa with a sensitivity of 11.3 counts per kPa. An array of up to 24 sensors was integrated into a flexible, stretchable circuit embedded in a thin (500 micron) silicone sheet using a multi-step layering fabrication process. Continuous magnet wires were wrapped around an alignment fixture, soldered to individual sensors in place and the entire circuit was transfer printed on to a silicone sheet. This assembly allows stretch corresponding to the fractional shortening of the heart muscles (up to 50%). The sleeve successfully measured static and dynamic pressures with a mechanical tensile tester and did not affect DCC device performance. Preliminary results demonstrated that the sleeve is robust enough to withstand >10000 cycles, compression forces from the DCC device and can achieve sensing range and repeatability suitable for procedural pressure monitoring for a DCC device. In addition to allowing performance measurements for iterating DCC device designs, the sensing sleeve can enable increased understanding of the response of the cardiovascular system to compressive assistance.

Copyright © 2015 by ASME
Topics: Pressure , Compression

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In