0

Full Content is available to subscribers

Subscribe/Learn More  >

Extremum Seeking Based Control Strategy for a Chilled-Water Plant With Parallel Chillers

[+] Author Affiliations
Baojie Mu, Yaoyu Li

The University of Texas at Dallas, Richardson, TX

Timothy I. Salsbury, John M. House

Johnson Controls, Inc., Milwaukee, WI

Paper No. DSCC2015-9949, pp. V002T29A005; 11 pages
doi:10.1115/DSCC2015-9949
From:
  • ASME 2015 Dynamic Systems and Control Conference
  • Volume 2: Diagnostics and Detection; Drilling; Dynamics and Control of Wind Energy Systems; Energy Harvesting; Estimation and Identification; Flexible and Smart Structure Control; Fuels Cells/Energy Storage; Human Robot Interaction; HVAC Building Energy Management; Industrial Applications; Intelligent Transportation Systems; Manufacturing; Mechatronics; Modelling and Validation; Motion and Vibration Control Applications
  • Columbus, Ohio, USA, October 28–30, 2015
  • Conference Sponsors: Dynamic Systems and Control Division
  • ISBN: 978-0-7918-5725-0
  • Copyright © 2015 by ASME

abstract

Chilled-water plants with multiple chillers are the backbone of ventilation and air conditioning (VAC) systems for commercial buildings. A penalty function based multivariate extremum seeking control (ESC) strategy is proposed in this paper for maximizing the energy efficiency in real time for a variable primary flow (VPF) chilled-water plant with parallel chillers. The proposed ESC algorithm takes the total power consumption (chiller compressors + cooling tower fan + condenser water pumps + penalty terms if inputs saturation occurs) as feedback, and tower fan air flow, condenser water flows and evaporator leaving chilled-water temperature setpoint as plant inputs (ESC outputs). A band-pass filter array is used in place of the conventional high-pass filter at the plant output so as to reduce the cross-channel interference. Chiller sequencing is also enabled with input saturation related signals. A Modelica based dynamic simulation model is developed for a chilled-water plant with two parallel chillers, one cooling tower, one air-handling unit and one zone. Simulation results under several testing conditions validate the effectiveness of the proposed model-free control strategy, as well as the significant energy saving.

Copyright © 2015 by ASME
Topics: Water

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In