0

Full Content is available to subscribers

Subscribe/Learn More  >

CFD Simulation and Experimental Data for a Fixed Heat Load Natural Draft Air-Cooled Heat Exchanger With Cold Inflow Mitigation

[+] Author Affiliations
Christopher C. M. Chu, Md. Mizanur Rahman, Sivakumar Kumaresan

Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia

Paper No. POWER2015-49020, pp. V001T12A001; 6 pages
doi:10.1115/POWER2015-49020
From:
  • ASME 2015 Power Conference collocated with the ASME 2015 9th International Conference on Energy Sustainability, the ASME 2015 13th International Conference on Fuel Cell Science, Engineering and Technology, and the ASME 2015 Nuclear Forum
  • ASME 2015 Power Conference
  • San Diego, California, USA, June 28–July 2, 2015
  • Conference Sponsors: Power Division
  • ISBN: 978-0-7918-5660-4
  • Copyright © 2015 by ASME

abstract

CFD simulation was carried out to corroborate experimental data at fixed heat load of nominally 2.3kW from a natural draft heat exchanger of face dimensions of 0.75m × 0.75m, with or without mitigation of the cold inflow at the chimney exit, where mitigation by installing wire mesh on top of the chimney has been shown by the experiments to enhance air flow rate. A chimney model was simulated at fixed heat loads in a still surrounding at ambient temperature of 30 degree Celsius and atmospheric pressure for two modes: Mode 1 and Mode 0 for with and without a flow resistor (wire mesh) respectively at the top exit. It was found that the simulation could reproduce most of the trends of the experimental data, but had a tendency to magnify the detrimental effects of cold inflow and exaggerate the remedial action of wire mesh in preventing cold inflow, as reflected by the ratio of Mode 1 to Mode 0 air mass flowrate by a factor of up to 2.36, compared to 1.50 in the experimental data. In both simulation and experiment, the average air flow rates obtained at chimney heights of 0.35m, 0.65m, 0.95m and 1.25m, showed progressive increase of air mass flow rate for all cases. Both experimental and simulated heat gain in Mode 0 were more or less constant until the highest chimney height where they showed apparent breakout upwards, whereas in Mode 1 the experimental heat gains gently reduced to a plateau while the simulated heat gains hovered at around 2.3kW. The back calculated values of Mode 0 experimental outlet temperature at between 140 to 240°C raises concern of hotspot in some electronic components by the ineffectiveness of chimney systems without cold inflow mitigation. Further experiments of similar scale with steadier control of heat flux and heating temperature, and simulating with other turbulence models in transient mode will improve understanding in both Mode 0 and Mode 1 of operation.

Copyright © 2015 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In