0

Full Content is available to subscribers

Subscribe/Learn More  >

Strategy for Mitigating AC Voltage on Light Rail Systems’ Interactions With Utility AC Power Distribution Systems

[+] Author Affiliations
Manjit Singh Khalsa, Krishan Sabherwal

Santa Clara Valley Transportation Authority, San Jose, CA

Paper No. JRC2015-5748, pp. V001T09A004; 14 pages
doi:10.1115/JRC2015-5748
From:
  • 2015 Joint Rail Conference
  • 2015 Joint Rail Conference
  • San Jose, California, USA, March 23–26, 2015
  • Conference Sponsors: Rail Transportation Division
  • ISBN: 978-0-7918-5645-1
  • Copyright © 2015 by ASME

abstract

Light rail systems interact with utility AC power distribution systems in many areas where running rails run parallel to the utility AC power transmission and distribution lines. This interaction may produce a 60Hz voltage on the running rail relative to the earth, adjacent to that the running rail. Since the running rails on modern systems are reasonably well isolated, this can result in potentials that can cause significant AC voltage on the rail that can cause instrumentation problems and personnel safety issues working on right-of-way (ROW). This effect is generally seen in areas where electrical distribution lines (power lines) run parallel to the running rail.

This paper will describe methodology used to mitigate the problems by selecting a suitable capacitor filter bank network that provides a highly conductive path for the induced AC voltages between the substation grounding grid and the running rail at the traction power substation location. The filter actually provides lower resistance to AC than the resistance to the ground, thus from an AC standpoint, the running rails are connected to the earth at that location. This drains much of the AC potential between running rail and the earth thus greatly lessening this potential even at significant distance from the substation. The filter network provides no path for DC current so it does not increase stray traction earth currents produced by rail drop voltage from an accelerating train. The adequate measurement and verification (M & V) techniques are adopted to achieve desired results.

The paper describes a cost effective solution comprising of an RC network filter with NEMA 3R rating enclosure, along with monitoring devices for monitoring DC and AC voltages and currents at the negative rail. These devices are installed and tested to mitigate the stray current issues successfully at the Valley Transportation Authority’s (VTA) traction power substation #31.

Copyright © 2015 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In