Risk Assessment of Emergency Diesel Generator Subject to Design Basis Earthquake Shaking

[+] Author Affiliations
Patxi Uriz

Exponent – Failure Analysis Associates, Menlo Park, CA

Troy A. Morgan

Exponent – Failure Analysis Associates, New York, NY

Paper No. IMECE2014-39569, pp. V014T08A026; 8 pages
doi:10.1115/IMECE2014-39569
From:
  • ASME 2014 International Mechanical Engineering Congress and Exposition
  • Volume 14: Emerging Technologies; Engineering Management, Safety, Ethics, Society, and Education; Materials: Genetics to Structures
  • Montreal, Quebec, Canada, November 14–20, 2014
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-4963-7
  • Copyright © 2014 by ASME

abstract

A monitoring system intended to track vibrations associated with the electric generation of an emergency diesel generator (EDG) at a nuclear power plant was originally installed to trip generators during potential out-of-balance shaking. Years after original installation, plant engineers raised questions as to whether the monitoring system would have functioned properly in the event of excessive vibrations associated with earthquake ground shaking. As part of the plant’s examination of this issue, analytical models were developed for three vibration transducers via experimental characterization. A suite of ground motion records were selected and scaled such that their mean and dispersion was representative of the design basis event (DBE) level of intensity at the plant site. The scaled suite of ground motions was used as an input for a three-dimensional analytical model representing the structure and soil-foundation interface where the EDGs were installed. The voltage signal from the analytical transducer model provided input to the physical vibration alarm monitor. This monitor filters the vibration transducer signal and generates an output to a time delay relay that will trip the EDG if the output from the vibration monitor is not reset within five seconds. The analysis and testing completed and described in this paper concluded that a DBE would not have caused the vibration monitoring circuit to spuriously trip the EDGs.

Copyright © 2014 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In