0

The Model V84.3 Shot Tests: Compressor Flow Field Measurements and Evaluation PUBLIC ACCESS

[+] Author Affiliations
M. Janssen, R. Mönig, J. Seume

Siemens AG, Mülheim, Germany

H. Hönen, R. Lösch-Schloms, H. E. Gallus

Rheinisch Westfälische Technische Hochschule, Aachen, Germany

Paper No. 94-GT-462, pp. V001T01A147; 11 pages
doi:10.1115/94-GT-462
From:
  • ASME 1994 International Gas Turbine and Aeroengine Congress and Exposition
  • Volume 1: Turbomachinery
  • The Hague, Netherlands, June 13–16, 1994
  • Conference Sponsors: International Gas Turbine Institute
  • ISBN: 978-0-7918-7883-5
  • Copyright © 1994 by ASME

abstract

Detailed experimental investigations were carried out at the Siemens test-facility in Berlin to validate and develop further the compressor design of the Model V84.3 gas turbine and to generate a comprehensive data base for the verification of the flow calculation programs. The test facility enables Siemens to confirm the design with regard to performance and reliability in the full scale machine under full load and off-design condition.

Various measuring techniques well established in the laboratory were applied to the full scale compressor to examine the flow field. Along with rather conventional 5-hole probes for measuring the flow field in the core region, miniaturized 3-hole probes were developed at the Turbomachinery Laboratory of the Technical University of Aachen, tested and finally used for the measurements of endwall boundary layer profiles and their development throughout the compressor. In addition to the probe measurements, wall static-pressure measurements, as well as probed vane measurements, were carried out.

The paper briefly describes the test facility, the compressor under investigation, and the instrumentation for the flow measurements. A comparison of the 3-hole and 5-hole probe measurements is presented. The experimental results are compared with calculated results taken from a two-dimensional off-design calculation program with standard loss models. By means of the measured static-pressure rise at the casing wall and the total pressure distributions downstream of the rotor rows, a modification of the loss modeling was performed. The calculated flow field is compared to the results of the 3-hole and 5-hole probe measurements in terms of radial distributions for flow angle. Mach number and total pressure.

Copyright © 1994 by ASME
This article is only available in the PDF format.

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In