0

Full Content is available to subscribers

Subscribe/Learn More  >

Optimal Design and Experimental Validation of a New No-Cuff Blood Pressure Sensor Based on a New Finite Element Model

[+] Author Affiliations
Tse-Yi Tu, Paul C.-P. Chao, Yung-Hua Kao

National Chiao Tung University, Hsinchu, Taiwan

Yung-Pin Lee

MedSense Inc., Hsinchu County, Taiwan

Paper No. DETC2014-35552, pp. V008T11A014; 5 pages
doi:10.1115/DETC2014-35552
From:
  • ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
  • Volume 8: 26th Conference on Mechanical Vibration and Noise
  • Buffalo, New York, USA, August 17–20, 2014
  • Conference Sponsors: Design Engineering Division, Computers and Information in Engineering Division
  • ISBN: 978-0-7918-4641-4
  • Copyright © 2014 by ASME

abstract

A new multi-physics finite element model (FEM) on the vibration of the radial artery on the wrist is built by this study to predict vibration of wrist artery vessel vibration and then diastolic and systolic blood pressures. The FEM includes the sensor of gel capsule and strain-sensing electrodes, skin, bones and muscles. The vibrations of skin surface and the sensor module are successfully simulated by the established FEM. The resulted vibratory deformation of the sensor electrodes are further transformed to resistance variations to mimic realistic electronics of the front-end readout circuit via establishing a cross-discipline sub-FEM model. The established FEM can is particularly customized to varied ages, weights, heights, genders, and special cardiovascular diseases of users. The customization can be performed in a fashion of one-time calibration by medical staff and/or medical staff. With the customized FEM in high accuracy level, the diastolic and systolic pressures can be accurately predicted by the simulated output resistance variation. Based on simulation FEMs, the design of the pulse sensor is successfully optimized via the processes of Taguchi and numerical methods. The measurements are also conducted to a dozen of subjects. It shows that the designed novel blood pressure sensor is capable of sensing the blood pressure to require accuracy level of the error less than 10% as compared to commercial counterparts with a cumbersome cuff.

Copyright © 2014 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In