0

Full Content is available to subscribers

Subscribe/Learn More  >

Effects of Prosthesis Mass on Hip Energetics, Prosthetic Knee Torque, and Prosthetic Knee Stiffness and Damping Parameters Required for Transfemoral Amputees to Walk With Normative Kinematics

[+] Author Affiliations
Yashraj S. Narang, Amos G. Winter, V

Massachusetts Institute of Technology, Cambridge, MA

Paper No. DETC2014-35065, pp. V05AT08A017; 8 pages
doi:10.1115/DETC2014-35065
From:
  • ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
  • Volume 5A: 38th Mechanisms and Robotics Conference
  • Buffalo, New York, USA, August 17–20, 2014
  • Conference Sponsors: Design Engineering Division, Computers and Information in Engineering Division
  • ISBN: 978-0-7918-4636-0
  • Copyright © 2014 by ASME

abstract

We quantify how the hip energetics and knee torque required for an above-knee prosthesis user to walk with the kinematics of able-bodied humans vary with the inertial properties of the prosthesis. We also select and optimize passive mechanical components for a prosthetic knee to accurately reproduce the required knee torque.

Previous theoretical studies have typically investigated the effects of prosthesis inertial properties on energetic parameters by modifying both mass and mass distribution of the prosthesis and computing kinetic and energetic parameters only during swing. Using inverse dynamics, we determined the effects of independently modifying mass and mass distribution of the prosthesis, and we computed parameters during both stance and swing. Results showed that reducing prosthesis mass significantly affected hip energetics, whereas reducing mass distribution did not. Reducing prosthesis mass to 25% of the mass of a physiological leg decreased peak stance hip power by 26%, average swing hip power by 74%, and absolute hip work over the gait cycle by 22%.

Previous studies have also typically optimized prosthetic knee components to reproduce the knee torque generated by able-bodied humans walking with normative kinematics. However, because the prosthetic leg of an above-knee prosthesis user weighs significantly less than a physiological leg, the knee torque required for above-knee prosthesis users to walk with these kinematics may be significantly different. Again using inverse dynamics, it was found that changes in prosthesis mass and mass distribution significantly affected this required torque. Reducing the mass of the prosthesis to 25% of the mass of the physiological leg increased peak stance torque by 43% and decreased peak swing torque by 76%.

The knee power required for an above-knee prosthesis user to walk with the kinematics of able-bodied humans was analyzed to select passive mechanical components for the prosthetic knee. The coefficients of the components were then optimized to replicate the torque required to walk with the kinematics of able-bodied humans. A prosthetic knee containing a single linear spring and two constant-force dampers was found to accurately replicate the targeted torque (R2=0.90 for a typical prosthesis). Optimal spring coefficients were found to be relatively insensitive to mass alterations of the prosthetic leg, but optimal damping coefficients were sensitive. In particular, as the masses of the segments of the prosthetic leg were altered between 25% and 100% of able-bodied values, the optimal damping coefficient of the second damper varied by 330%, with foot mass alterations having the greatest effect on its value.

Copyright © 2014 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In