0

Full Content is available to subscribers

Subscribe/Learn More  >

Development of an ADL Assistance Apparatus for Upper Limbs and Evaluation of Muscle and Cerebral Activity

[+] Author Affiliations
Eiichirou Tanaka

Shibaura Institute of Technology, Saitama, Japan

Shozo Saegusa

Hiroshima University, Higashi-Hiroshima, Japan

Yasuo Iwasaki

Toho University, Tokyo, Japan

Louis Yuge

Hiroshima University, Hiroshima, Japan

Paper No. DETC2014-34914, pp. V05AT08A015; 7 pages
doi:10.1115/DETC2014-34914
From:
  • ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
  • Volume 5A: 38th Mechanisms and Robotics Conference
  • Buffalo, New York, USA, August 17–20, 2014
  • Conference Sponsors: Design Engineering Division, Computers and Information in Engineering Division
  • ISBN: 978-0-7918-4636-0
  • Copyright © 2014 by ASME

abstract

We developed an assistance apparatus for upper limbs for patients who can control their finger but they cannot lift up their arms themselves, for example myopathy and hemiplegic patients. The mechanism of assistance is utilized the differential gears to lose the weight and volume of the mechanical arm. That enabled us to configure three motors to drive two DOFs (Degrees of freedom) for the shoulder and one DOF for the elbow around the root of the mechanical arm. This arm has two support trays, for wrist and upper arm. Furthermore, to realize other ADL (activities of daily living) motions (for instance, eating, writing, putting on makeup, wiping his/her face, and so on) them selves, we proposed to control the device using the targeted posture map for the mechanical arm. To be able to choose the appropriate input for each patient, various input interfaces, for example, joy-stick, push buttons, sensor glove using bending sensors, and so on, are equipped.

In general, even though a human behaves an atonic motion, the maximum voluntary contraction (%MVC) outputs at least from 5 to 10%. The usage of this apparatus is to move the user’s upper limbs with dependence completely, and the purpose of this apparatus is to decrease the value of %MVC up to approximately 10%. Therefore, in this paper, the muscles of the user were evaluated with the ratio of %MVC. To confirm the effectiveness of assistance ability, we measured muscle activity while using the device, and compared the %MVC data between using the device or not. As a result, the activity decreased up to 80%, and the effectiveness of this device could be confirmed.

Finally, to expand the usage of this apparatus to encompass Neuro-Rehabilitation as well, we measured cerebral activity while using the device for rehabilitation with a near-infrared spectroscopy (NIRS). Then we compared the data from using the device or not, and input motion from a third person. By using this device, the cerebral activity decreased especially when the target motion was complex. However, when the subject input the motion themselves, the cerebral activity increased more than when the data is input by a third person, especially, when the target motion was complex. Therefore, for use in Neuro-Rehabilitation, we found it is important the subject input the target motion him/herself.

Copyright © 2014 by ASME
Topics: Muscle

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In