0

Full Content is available to subscribers

Subscribe/Learn More  >

Assessment of an Existing Hot Tap Connection on the Bord Gáis Éireann Brighouse Bay Gas Export Terminal

[+] Author Affiliations
Peter Boothby, Robert Andrews, Simon Slater

MACAW Engineering Ltd., Newcastle Upon Tyne, UK

Graham Canty

Bord Gáis Éireann, Cork, Ireland

Paper No. IPC2014-33645, pp. V003T07A053; 9 pages
doi:10.1115/IPC2014-33645
From:
  • 2014 10th International Pipeline Conference
  • Volume 3: Materials and Joining; Risk and Reliability
  • Calgary, Alberta, Canada, September 29–October 3, 2014
  • Conference Sponsors: Pipeline Division
  • ISBN: 978-0-7918-4612-4
  • Copyright © 2014 by ASME

abstract

A previous IPC conference paper (1) described the technical challenges associated with the installation of a new hot tap connection, supplementary to an existing hot tap connection, on the Bord Gáis Éireann Brighouse Bay high pressure gas export terminal in the UK. Work carried out to verify that the hot tap connection would be fit for purpose included a pipe stress analysis, Finite Element Analysis (FEA) and Engineering Critical Assessment (ECA). These assessments were performed because the split tee shell thickness and consequently also the circumferential fillet weld leg lengths did not achieve the 2 × carrier pipe thickness criterion required by UK specifications for applications where design stress levels exceed 30% specified minimum yield strength.

Subsequently, it was identified that the existing hot tap connection installed in 2001 also did not meet the 2 × carrier pipe thickness criterion. Furthermore the material grade was lower than that for newer hot tap, i.e. P355 compared with P460 and the tee had been chamfered down from 50 mm to 40 mm at the ends, leading to reduced section circumferential fillet welds. This resulted in a leaner design than that for the newer hot tap and an ASME B31.3 area replacement calculation revealed that the area replacement ratio barely achieved the 1.0 requirement of the code suggesting a limited tolerance to system loading. Consequently similar stress analysis, FEA and ECA assessments to those previously undertaken were also subsequently performed for the existing hot tap connection. This paper provides details of the analyses and results obtained to determine the integrity of the existing hot tap split tee assembly which required a bespoke approach and a need to challenge conventional thinking.

Copyright © 2014 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In