Admission of Bypass Steam Into a Water Cooled Condenser and Air Cooled Condenser: Similarities, Differences and Areas of Concern

[+] Author Affiliations
Ranga Nadig

Maarky Thermal Systems Inc., Cherry Hill, NJ

Dave Sanderlin

SPIG USA Inc., San Diego, CA

Paper No. POWER2014-32249, pp. V001T03A009; 6 pages
doi:10.1115/POWER2014-32249
From:
  • ASME 2014 Power Conference
  • Volume 1: Fuels and Combustion, Material Handling, Emissions; Steam Generators; Heat Exchangers and Cooling Systems; Turbines, Generators and Auxiliaries; Plant Operations and Maintenance; Reliability, Availability and Maintainability (RAM); Plant Systems, Structures, Components and Materials Issues
  • Baltimore, Maryland, USA, July 28–31, 2014
  • Conference Sponsors: Power Division
  • ISBN: 978-0-7918-4608-7
  • Copyright © 2014 by ASME

abstract

In power plant locations with adequate supply of cooling water the steam from the steam turbine is condensed in a water cooled condenser. In most instances circulating water from the cooling tower is used to condense the turbine exhaust steam. In other instances once through cooling is deployed wherein water from a lake, river or sea is used to condense the turbine exhaust steam. In water challenged locations or locations where wet cooling cannot be deployed due to permitting or regulatory issues, the steam from the steam turbine is condensed in an air cooled condenser (ACC) wherein ambient air is used to cool and condense the turbine exhaust steam. In a combined cycle plant, during normal operation, the water or air cooled condenser condenses the turbine exhaust steam. During bypass operation, when the steam turbine is out of service, the high-pressure steam from the HRSG is attemperated in a pressure reducing/desuperheating (PRD) valve and then admitted into the water cooled or air cooled condenser. The bypass steam flow is substantially higher than the design turbine exhaust steam flow and the duration of bypass operation can vary from a few hours to several weeks.

The requirements for admission of bypass steam into a water cooled condenser are substantially different from that for an air cooled condenser. In a water cooled condenser the bypass steam is admitted in the steam dome. The bypass steam as well as the turbine exhaust steam is condensed outside the tubes. In an air cooled condenser the bypass steam is admitted in the large diameter steam duct. The bypass, as well as the turbine exhaust steam (normal operation), is condensed inside the tubes. There are similarities and differences in the requirements for admission of bypass steam into a water cooled and air cooled condenser. The differences must be identified and addressed to ensure safe and reliable performance of the condenser.

Copyright © 2014 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In