0

Full Content is available to subscribers

Subscribe/Learn More  >

Using Explicit Finite Element Analysis to Simulate the Structural Damage Associated With an Internal Detonation in a Heat Exchanger

[+] Author Affiliations
Phillip E. Prueter

The Equity Engineering Group, Inc., Shaker Heights, OH

Paper No. PVP2014-28893, pp. V002T02A014; 13 pages
doi:10.1115/PVP2014-28893
From:
  • ASME 2014 Pressure Vessels and Piping Conference
  • Volume 2: Computer Technology and Bolted Joints
  • Anaheim, California, USA, July 20–24, 2014
  • Conference Sponsors: Pressure Vessels and Piping Division
  • ISBN: 978-0-7918-4599-8
  • Copyright © 2014 by ASME

abstract

Developing the realistic blast loading associated with an internal detonation occurring within a pressure vessel or heat exchanger is challenging. Unlike evaluation of external blast loading on structures due to far-field explosions, where typical overpressure-time histories can be reasonably defined based on empirical data, investigating confined detonations presents additional complications. The subsequent impulsive peak reflected overpressure from confined detonations acting on a structure can be extremely high due to the close proximity of the blast source to the vessel wall or pressure boundary. This establishes the possibility of significant structural damage for process equipment subjected to an internal detonation, even for relatively modest amounts of concentrated explosive products.

This paper discusses the underlying theory of blast analysis and examines the practical application of non-linear, finite element based, explicit computational techniques for simulating the load acting on a structure due to internal and external blasts. The investigation of a recent, real-life industry failure of a heat exchanger due to a suspected internal detonation is discussed. Explicit, three-dimensional blast analysis is performed on the heat exchanger in question, and an internal detonation is simulated to reasonably replicate the considerable damage actually observed in the field. This analysis permits the determination of an approximate amount of concentrated product that caused the accidental explosion; that is, the plausible equivalent amount of explosives is back-calculated based on the predicted damage to the finite element model of the equipment in question. Computational iterations of varying charge amounts are performed and the predicted amount of permanent damage is documented so sensitivity to the hypothesized charge amount can be quantified. Furthermore, explicit blast analysis of nearby equipment is performed.

In this investigation, computational results for both the heat exchanger (subjected to internal blast loading) and surrounding equipment (subjected to external blast loading) are in good agreement with the measured plastic deformations and failure modes that were actually observed in the field. Commentary on the likely detonation event that caused the significant damage observed is provided. Additionally, an advanced finite element failure criterion that is driven by plastic yielding is employed where portions of the computational model are removed from the simulation once a user-defined strain threshold is reached. This approach facilitates simulation of the gross heat exchanger pressure boundary failure actually observed in this case. The explicit finite element based analyses discussed in this study reasonably predict the structural response and damage characteristics corresponding to a recent, real-life industry failure.

Copyright © 2014 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In