0

Full Content is available to subscribers

Subscribe/Learn More  >

Performance Analysis of a Simplified Model of Cooling Load for a Typical Office Building

[+] Author Affiliations
Oluwaseyi T. Ogunsola, Li Song

University of Oklahoma, Norman, OK

Paper No. IMECE2013-64040, pp. V011T06A025; 8 pages
doi:10.1115/IMECE2013-64040
From:
  • ASME 2013 International Mechanical Engineering Congress and Exposition
  • Volume 11: Emerging Technologies
  • San Diego, California, USA, November 15–21, 2013
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-5640-6
  • Copyright © 2013 by ASME

abstract

Buildings are responsible for at least 40% of energy use in most countries of the world, and for up to 21% of greenhouse gas emissions globally. As this trend continues, real-time building load measurements are essential for dynamic load response control, understanding and improvement of load distributions and profiles, and for climate-responsive design, particularly in commercial buildings. The focus in this paper is the cooling load, which is the rate at which heat must be removed from the controlled zone to maintain the desired temperature. Estimation of maximum cooling load is necessary for sizing of cooling equipments. However, details needed for whole-building simulation are often unreliable or unavailable. As such, simplified models with reasonable accuracy and computational requirements are often used. A cyber-physical system, integration of physical sensors and mathematical model, is proposed in this paper for cooling load estimation. The physical sensor measurements are limited to outside air temperature, solar radiation, room air temperature, and building plug load. Meanwhile, resistance-capacitance (RC) concept was adopted to describe the physics and dynamics of the building envelope for its simplicity and reasonable computational requirements. The cyber-physical system was tested using a typical office having two thermal zones and compared with simulation results from EnergyPlus, a whole building simulation program. Phenomenon such as infiltration, inter-zone air mixing, and air moisture control were not taken into account for the model. Results are presented to determine the accuracy of the simplified model for cooling load estimation.

Copyright © 2013 by ASME
Topics: Cooling , Stress

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In