A Numerical Study for Contained Cold Aisle Data Center Using CRAC and Server Calibrated Fan Curves

[+] Author Affiliations
Sami A. Alkharabsheh, Bahgat G. Sammakia

State University of New York at Binghamton, Binghamton, NY

Saurabh Shrivastava

PANDUIT Corporation, Tinley Park, IL

Roger Schmidt

IBM Corporation, Poughkeepsie, NY

Paper No. IMECE2013-65145, pp. V010T11A085; 8 pages
doi:10.1115/IMECE2013-65145
From:
  • ASME 2013 International Mechanical Engineering Congress and Exposition
  • Volume 10: Micro- and Nano-Systems Engineering and Packaging
  • San Diego, California, USA, November 15–21, 2013
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-5639-0
  • Copyright © 2013 by ASME

abstract

In the present work, we demonstrate the effect of Cold Aisle Containment Systems (CACS) on the airflow and temperature distribution inside a representative data center. Computational Fluid Dynamics (CFD) is used to conduct this analysis. This study includes calibrated fan curves in the Computer Room Air Conditioner (CRAC) and the servers in order to capture the impact of pressure changes on the flow field. The system characteristics curve for the open (uncontained) system and contained system including the leakage effect is established. Since the IT-equipment has a crucial effect on the performance of contained systems, the individual and combined effect of fully enclosing the cold aisle and IT-equipment are investigated. Partially contained systems including doors only and ceilings only configurations are also considered in this study. Steady state and dynamic scenarios are simulated to characterize different containment systems.

It is found that the pressure inside the fully contained system is determined by the IT-equipment as well as the geometrical obstructions of fully containing the cold aisle. Increasing the pressure due to enclosing the cold aisle is reduced by introducing IT-equipment, load banks in this case, which leads to a reduction of the total static pressure and an increase of the flow rate. It is also found that the fully contained system presents the best configurations in achieving low and uniform temperature distribution; however, partially contained systems can be a good solution if a certain cold air provision is maintained during operation. The dynamic analysis shows a significant increase in the safe time at full CRAC failure scenario compared with uncontained system due to utilizing the trapped cold air inside the plenum by the load banks fans.

Copyright © 2013 by ASME
Topics: Data centers

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In