0

Full Content is available to subscribers

Subscribe/Learn More  >

Misinterpretation of Stenosis Severity in the Presence of Serial Coronary Stenoses

[+] Author Affiliations
Gavin A. D’Souza, Srikara V. Peelukhana, Rupak K. Banerjee

University of Cincinnati, Cincinnati, OH

Paper No. FMD2013-16180, pp. V001T01A005; 2 pages
doi:10.1115/FMD2013-16180
From:
  • ASME 2013 Conference on Frontiers in Medical Devices: Applications of Computer Modeling and Simulation
  • ASME 2013 Conference on Frontiers in Medical Devices: Applications of Computer Modeling and Simulation
  • Washington, DC, USA, September 11–13, 2013
  • Conference Sponsors: Bioengineering Division
  • ISBN: 978-0-7918-5600-0
  • Copyright © 2013 by ASME

abstract

Diagnosis of the functional severity of an epicardial coronary stenosis using parameters like Fractional Flow Reserve, FFR (ratio of distal to proximal pressure of a stenotic region), might be affected in the presence of an additional downstream stenosis. In order to assess this effect, we have performed an in-vitro experiment which is used to validate a computational study. Three combinations of serial stenoses were tested: 80%-64%, 80%-80% and 80%-90% area stenosis (AS). The physiological mean hyperemic flow (flow at maximal arterial dilatation) values were obtained using an in-vitro experimental set-up. These flow rates were used as steady flow inputs by time-averaging the spatially averaged flow pulse over two cardiac cycles for the computational study. FFR values were calculated at hyperemic flow using both the experimental and numerical pressure data. As the downstream severity increased from 64% AS to 80% AS, hyperemic coronary flow decreased from 136.4 ml/min to 126.4 ml/min. Flow decreased further to 90.7 ml/min with a downstream severity of 90% AS. FFR of the intermediate stenosis increased from 0.76 to 0.79 and further to 0.88 as the downstream stenosis increased from 64% to 80% with a final severity of 90% AS. Similarly, numerically obtained FFR values increased to 0.83, 0.80 and 0.92 for the corresponding cases indicating an error within 7% of the experimental values. These results indicate that the presence of a downstream stenosis might lead to a clinical misinterpretation of the upstream stenosis severity.

Copyright © 2013 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In