Solid and Fluid Simulations of Vertebral Artery Stenosis Treated With Stents With Different Shapes of Link

[+] Author Affiliations
Aike Qiao, Zhanzhu Zhang

Beijing University of Technology, Beijing, China

Paper No. SBC2013-14062, pp. V01AT20A003; 2 pages
doi:10.1115/SBC2013-14062
From:
  • ASME 2013 Summer Bioengineering Conference
  • Volume 1A: Abdominal Aortic Aneurysms; Active and Reactive Soft Matter; Atherosclerosis; BioFluid Mechanics; Education; Biotransport Phenomena; Bone, Joint and Spine Mechanics; Brain Injury; Cardiac Mechanics; Cardiovascular Devices, Fluids and Imaging; Cartilage and Disc Mechanics; Cell and Tissue Engineering; Cerebral Aneurysms; Computational Biofluid Dynamics; Device Design, Human Dynamics, and Rehabilitation; Drug Delivery and Disease Treatment; Engineered Cellular Environments
  • Sunriver, Oregon, USA, June 26–29, 2013
  • Conference Sponsors: Bioengineering Division
  • ISBN: 978-0-7918-5560-7
  • Copyright © 2013 by ASME

abstract

Stenting technology has emerged as an effective alternative for treating arterial stenosis, which recovers blood fluency through mechanical scaffold using struts. Different kinds of endovascular stents cause varying degrees of injury on the artery wall, inducing different ratios of post-operative in-stent restenosis (ISR). Therefore, the design of stent structure has a significant influence on the therapeutic effect of stent intervention. From the viewpoint of solid mechanics, the artery is subjected to long-term press by stent strut after intervention, leading to external mechanical force acting on artery. Straightening, mechanical stress, and stress concentration occurred, causing in-stent intimal hyperplasia extremely, which consequently induce ISR. From the viewpoint of hemodynamics, hemodynamic environment is changed to some extent after stenting. As a result, local blood flow is changed greatly. Vortex and low WSS occur, promoting thrombosis and intimal hyperplasia, which induce ISR more easily. To investigate the effect of stents with different links on treating stenotic vertebral artery and the relation between the shape of link and ISR, as well as provide scientific guidelines for designing stent structure and selecting stent in clinical procedure, numerical simulations of solid mechanics and hemodynamics were performed in this paper, which coupled the boundaries of stent, plaque and blood in the stented vertebral arteries using three kinds of stent with different links.

Copyright © 2013 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In