Dynamically Controlled Long Duration Operation of a Highly Energy Efficient Chiller-Less Data Center Test Facility

[+] Author Affiliations
Milnes P. David, Robert E. Simons, Roger Schmidt

IBM Systems & Technology Group, Poughkeepsie, NY

Pritish R. Parida, Mark D. Schultz, Michael Gaynes, Timothy J. Chainer

IBM T. J. Watson Research Center, Yorktown Heights, NY

Paper No. IPACK2013-73183, pp. V002T09A014; 9 pages
doi:10.1115/IPACK2013-73183
From:
  • ASME 2013 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems
  • Volume 2: Thermal Management; Data Centers and Energy Efficient Electronic Systems
  • Burlingame, California, USA, July 16–18, 2013
  • Conference Sponsors: Electronic and Photonic Packaging Division
  • ISBN: 978-0-7918-5576-8
  • Copyright © 2013 by ASME

abstract

Data center energy consumption makes up a significant and rapidly growing portion of the national energy use. A large fraction of this energy consumption, in the range of 25%–40%, is used by the data center cooling infrastructure, particularly by the computer room air handlers (CRAH) and by the chiller plant. A joint US Department of Energy and IBM effort investigated the use of warm water server cooling and water side economization to help improve energy efficiency in a volume server by minimizing the use of CRAH and chiller hours with the goal of reducing the ratio of cooling energy to IT energy from the conventional value of approximately 50% to less than 10%. Previous work focusing on system characterization and one day runs found significant energy savings as compared to a traditional chiller based data center. In the work reported in this paper we discuss the development and implementation of a dynamic control approach followed by details and results from a 60+ day run of the data center test facility starting May 11th, 2012. Results from this long term study found the average cooling energy consumption to be 3.5% of the IT energy, which is consistent with previous short one day runs. The implemented control scheme was also able to reliably control the water temperature to within 0.5°C of the set-point under most conditions and could react and stabilize to a new set-point in 30 minutes. The work presented demonstrates the high energy efficiency of a warm water cooled, water-side economized, chiller-less data center over a long sustained period of time and highlights the benefits of energy aware control to help limit cooling energy.

Copyright © 2013 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In