CFD Modeling of Indirect/Direct Evaporative Cooling Unit for Modular Data Center Applications

[+] Author Affiliations
Betsegaw Gebrehiwot, Nikhil Dhiman, Kasturi Rajagopalan, Dereje Agonafer

University of Texas at Arlington, Arlington, TX

Naveen Kannan, James Hoverson, Mike Kaler

Mestex, a Division of Mestek Inc., Dallas, TX

Paper No. IPACK2013-73302, pp. V002T08A054; 7 pages
doi:10.1115/IPACK2013-73302
From:
  • ASME 2013 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems
  • Volume 2: Thermal Management; Data Centers and Energy Efficient Electronic Systems
  • Burlingame, California, USA, July 16–18, 2013
  • Conference Sponsors: Electronic and Photonic Packaging Division
  • ISBN: 978-0-7918-5576-8
  • Copyright © 2013 by ASME

abstract

An information technology (IT) container needs to be supplied with cold air to cool IT equipment housed in it. The type of cooling system to be used depends on many factors including geographical location of the modular data center. Data centers located in regions where the climate is cold benefit from use of air-side economization (ASE) and those located in hot and dry climate benefit from use of direct and/or indirect evaporative cooling (DIEC) systems. In terms of energy saving, ASE, direct evaporative cooling (DEC) system, and indirect evaporative (IEC) systems are better than compressor based cooling systems such as computer room air conditioning (CRAC) units and air handling units (AHU).

In this study, an existing DIEC unit which can also be operated in ASE mode is modeled in a computational fluid dynamics (CFD) tool. The cooling unit is intended to be used for supplying cold air to a containerized data center with specified volume flow rate, dry-bulb temperature and relative humidity. The CFD model is compared with published data of the cooling unit to see how well the CFD model represents the actual system and few design improvement ideas are tested by modifying the CFD model and running simulations. Results show that supplying air horizontally or as a downdraft to an IT container has negligible effect on the overall system. Results also show that orientation of dampers and placement of blanking panels inside the mixing chamber could affect the lifespan of air filters.

Copyright © 2013 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In