Experimental Investigations of Droplet Deposition and Coalescense in Curved Pipes

[+] Author Affiliations
Hung Nguyen, Shoubo Wang, Ram S. Mohan, Ovadia Shoham

The University of Tulsa, Tulsa, OK

Gene Kouba

Chevron Energy Technology Co., Houston, TX

Paper No. IMECE2012-88365, pp. 2503-2508; 6 pages
doi:10.1115/IMECE2012-88365
From:
  • ASME 2012 International Mechanical Engineering Congress and Exposition
  • Volume 7: Fluids and Heat Transfer, Parts A, B, C, and D
  • Houston, Texas, USA, November 9–15, 2012
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-4523-3
  • Copyright © 2012 by ASME

abstract

Even though there have been several studies conducted by the industry on the use of different inlet devices for gas-liquid separation there have been limited laboratory and field evaluations on the use of external piping configurations as flow conditioning devices upstream of a separator inlet. The results of a systematic study of droplet deposition and coalescence in curved pipe and pipe fittings are reported in this paper. A facility has been designed consisting of two main test sections: a fixed horizontal straight pipe section and an interchangeable 180° return pipe section (or curved pipe section) of the same length. Both inlet and outlet to the 180° return are horizontal, but the plane of the 180° return pipe section can pivot about the axis of the inlet horizontal pipe to an angle as much as 10° downwards allowing downward flow in the return section. Various pipe fittings of different radius of curvature can be installed for comparison in the 180° return. Fittings evaluated in this study included: 180° pipe bend, 2 standard radius elbows (with radius of curvature of 1.5D), 2 long radius elbows (with radius of curvature of 6D), 2 target tee bend, and 2 cushion tee bend. Experiments have been carried out using water and air and varying gas velocities and liquid loadings. In order to compare the performance of geometries, Droplet Deposition Fractions (DDF) were measured in the horizontal straight pipe section and in the 180° return pipe section as a measure of coalescence efficiency. The results demonstrate that higher DDF occurs for curved fittings as compared to the straight pipe section. Two standard (short) radius elbows bend have approximately 10% DDF higher, whereas two long radius elbows along with 180° pipe bend perform better (by 15–20% DDF) than straight pipe. Additionally, no significant differences between DDF’s in three different inclination angles of a curved pipe were observed. It was found that the cushion tees and target tees can coalesce droplets at lower gas velocities but break up droplets at higher gas velocities. It can be concluded that 180° pipe bend or two 6D long radii elbows can serve as a droplet coalescer, a pair of cushion tees or target tee can also work as coalescer at low kinetic energy but as atomizers at high kinetic energy.

Copyright © 2012 by ASME
Topics: Drops , Pipes

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In