Tip Flowfield of a Low Aspect Ratio Circulation Control Wing With Spanwise Variation in Efflux

[+] Author Affiliations
Matthew Perry, David Miklosovic

U.S. Naval Academy, Annapolis, MD

Paper No. IMECE2012-85266, pp. 443-453; 11 pages
doi:10.1115/IMECE2012-85266
From:
  • ASME 2012 International Mechanical Engineering Congress and Exposition
  • Volume 1: Advances in Aerospace Technology
  • Houston, Texas, USA, November 9–15, 2012
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-4517-2

abstract

A stereoscopic particle image velocimetry (SPIV) system was used in a low-speed wind tunnel to measure the external flowfield of a circulation control (CC) wing having an aspect ratio of 1.1. This ongoing project, sponsored by the Office of Naval Research, sought to further the knowledge of the jet interactions and the wingtip vortex formation through 3-component, planar velocity surveys. The CC wing tested had a 20% elliptic airfoil section with a trailing edge Coanda surface that was intended to increase circulation control effectiveness through a segmented system that could create spanwise massflow efflux profiles.

To date, 1.2 TB of raw SPIV data have been acquired in one of two wake station planes at z/c = 1.25 over the vertical region of 0.13 < y/b < 0.87 (i.e, the tip region). The three-component velocity data revealed the nature of the interaction of the jet with the external flowfield and the temporal variability at an overall momentum coefficient of 0.08 with spanwise variations in the trailing edge efflux. The results from these tests will be used to quantify, for the first time, the effects of spanwise massflow distributions on the 3D velocity field near the trailing edge, the stall modes, jet interactions, and the overall performance of a CC wing of this geometry.

Topics: Wings

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In