0

Full Content is available to subscribers

Subscribe/Learn More  >

Research on Leak Test for Long Distance Gas Pipline

[+] Author Affiliations
Feng Yan, Qing Miao, Xiangdong Xue, Yubin Wang, Daquan Li, Jingnan Zhang

PetroChina Pipeline R&D Center, Langfang, China

Paper No. IPC2012-90068, pp. 89-95; 7 pages
doi:10.1115/IPC2012-90068
From:
  • 2012 9th International Pipeline Conference
  • Volume 1: Upstream Pipelines; Project Management; Design and Construction; Environment; Facilities Integrity Management; Operations and Maintenance; Pipeline Automation and Measurement
  • Calgary, Alberta, Canada, September 24–28, 2012
  • Conference Sponsors: International Petroleum Technology Institute, Pipeline Division
  • ISBN: 978-0-7918-4512-7
  • Copyright © 2012 by ASME

abstract

The main purpose of pre-service leak test is to prove the tightness of the pipeline system. It plays an important role to guarantee the safety operating of pipeline. However, the duration of leak test is different in different countries. If the duration of tightness test is longer, the tightness level can be sufficiently detected, which is benefit for pipeline safe operating, but the cost and the time of project must be extended; if the duration of tightness test is shorter, the defect of pipeline can not be fully exposed, which may be left hidden trouble for pipeline safe operating. Meanwhile, the tightness test may be influenced by many factors, for example the test medium, pipeline capacity, pressure, ambient temperature variation, leak detection methods, and so on. Therefore, it is unreasonable to leak test with same duration for different kinds of gas pipeline, which regulated in some standards, for example CSA Z662-11, BS EN1594:2000, ISO 13623:2008, GB 50251-2003, and so on. At the same time, those standards all regulated that the duration of tightness test should be properly extended while the pipeline capacity and ambient temperature variation obviously affect the accuracy of leak test, but the definite value is not regulated. In addition, they also regulated that the pressure increases or decreases during leak test shall be acceptable provided that it can be demonstrated through calculations that the pressure change is caused by ambient temperature variations, but there is no explicit calculation method. Now, the specified duration of leak test in different standards are all based on the engineering experience. Because there is no rational theory way, it makes the identification and modification of the duration for different kinds of pipeline become blind.

Based on the theory of fluid mechanics, material mechanics, elastic mechanics, a mathematical model about the duration of leak test for long distance gas pipeline is developed for the first time. The influences of the test medium, pipeline capacity, pressure, ambient temperature variation and other factors which may impact the duration of leak test are synthetically considered in the model. The experimental verification shows that the result calculated by the model is accurate. It can provide reliable theoretical guidance for determining reasonable leak test duration for long distance gas pipeline.

Copyright © 2012 by ASME
Topics: Leakage

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In