Application of Three Methods in Determining the Effectiveness of Surge Protection Systems in Gas Compressor Stations

[+] Author Affiliations
K. K. Botros

NOVA Research & Technology Center, Calgary, AB, Canada

D. Bakker

Suncor Energy, Calgary, AB, Canada

Paper No. IPC2012-90618, pp. 781-793; 13 pages
doi:10.1115/IPC2012-90618
From:
  • 2012 9th International Pipeline Conference
  • Volume 1: Upstream Pipelines; Project Management; Design and Construction; Environment; Facilities Integrity Management; Operations and Maintenance; Pipeline Automation and Measurement
  • Calgary, Alberta, Canada, September 24–28, 2012
  • Conference Sponsors: International Petroleum Technology Institute, Pipeline Division
  • ISBN: 978-0-7918-4512-7
  • Copyright © 2012 by ASME

abstract

Compression Systems are designed and operated in a manner to eliminate or minimize the potential for surge, which is a dynamic instability that is very detrimental to the integrity of the unit. Compressor surge can occur when compressors are subjected to rapid transients such as one following emergency shutdown (ESD) or power failure. To prevent this from occurring, compressor stations are designed with recycle systems and special types of recycle valves, which are required to open upon ESD. These recycle valves must have specific characteristics to cope with such fast transients and protect the compressor for undergoing surge. This paper describes three methods for determining the effectiveness of any specific recycle system and recycle valve characteristics. These three methods are: i) the concept of the Inertia number, ii) a simplified method based on system impedance, and iii) full dynamic simulation of the compression system. These three methods are applied to a high pressure ratio (up to 3.5) natural gas compressor station involving very high volume of piping and equipment contained within the recycle loop. There is a heat exchanger to utilize the heat of compression to heat the condensate separated downstream in the discharge scrubber, two large aerial coolers to cool the high temperature discharge gas from the compressor, and the discharge scrubber itself. This equipment and associated large volume capacitance contained therein presented a significant challenge and demand on the surge suppression system in all aspects of operation; particularly during ESD. Results are presented from all three methods which show the consistency and complementary nature of these methods.

Copyright © 2012 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In