0

Full Content is available to subscribers

Subscribe/Learn More  >

Theoretical and Experimental Investigation of Force Estimation Errors Using Active Magnetic Bearings With Embedded Hall Sensors

[+] Author Affiliations
Andreas Jauernik Voigt

Lloyd’s Register ODS, Copenhagen, Denmark

Ilmar F. Santos

Technical University of Denmark, Copenhagen, Denmark

Paper No. GT2012-68282, pp. 779-793; 15 pages
doi:10.1115/GT2012-68282
From:
  • ASME Turbo Expo 2012: Turbine Technical Conference and Exposition
  • Volume 7: Structures and Dynamics, Parts A and B
  • Copenhagen, Denmark, June 11–15, 2012
  • Conference Sponsors: International Gas Turbine Institute
  • ISBN: 978-0-7918-4473-1
  • Copyright © 2012 by ASME

abstract

This paper gives an original theoretical and experimental contribution to the issue of reducing force estimation errors, which arise when applying Active Magnetic Bearings (AMBs) with pole embedded Hall sensors for force quantification purposes. Motivated by the prospect of increasing the usability of AMBs by embedding Hall sensors instead of mounting these directly on the pole surfaces, force estimation errors are investigated both numerically and experimentally. A linearized version of the conventionally applied quadratic correspondence between measured Hall voltage and applied AMB force is suggested and investigated. A finite element (FE) model is constructed to study force error behavior as a function of rotor offset. The investigation confirms that the magnitude of the force error is dependent on how well the rotor is centered in the AMB. Furthermore, below a rotor offset corresponding to ∼20% of the nominal air gap the force estimation error is found to be reduced by the linearized force equation as compared to the quadratic force equation, which is supported by experimental results. Additionally the FE model is employed in a comparative study of the force estimation error behavior for pole embedded and pole surface mounted Hall sensors. It is shown that in a given range of bias currents and rotor offsets, pole embedded and surface mounted Hall sensors perform equally well for the four pole heteropolar flux-split radial AMB under investigation. Furthermore, frequency dependence of the Hall sensor sensitivity factors is investigated, and found to be non-existing, hence static calibration of Hall sensors is sufficient, even for dynamic testing purposes.

Copyright © 2012 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In