0

Full Content is available to subscribers

Subscribe/Learn More  >

Mixing in Large Scale Tanks: Part III — Predicting Slurry Pump Performance

[+] Author Affiliations
Robert A. Leishear, Richard A. Dimenna, David B. Stefanko, Si Y. Lee

Westinghouse Savannah River Corporation, Aiken, SC

Paper No. HT-FED2004-56209, pp. 785-794; 10 pages
doi:10.1115/HT-FED2004-56209
From:
  • ASME 2004 Heat Transfer/Fluids Engineering Summer Conference
  • Volume 4
  • Charlotte, North Carolina, USA, July 11–15, 2004
  • Conference Sponsors: Heat Transfer Division and Fluids Engineering Division
  • ISBN: 0-7918-4693-8 | eISBN: 0-7918-3740-8
  • Copyright © 2004 by ASME

abstract

This third in a series of four papers (Parts I–IV) presents the equations used for the initial evaluation of a pump’s ability to suspend solids and extends those equations to establish the minimum local velocity required to suspend those solids. This minimum velocity was used in a finite difference model in Part I to predict the ability of a pump to suspend, or slurry, solids that had settled on the bottom of a nuclear waste tank. To slurry waste, the Advanced Design Mixer Pump (ADMP) discharges a fluid jet that impinges on, shears, and then suspends the waste. Prior to the pump’s installation in a waste tank, the local velocity at a point in the flow required to suspend solids was found from available equations, material properties, and empirical data for similar pumps. Also, the computational fluids dynamics (CFD) model was validated in Part II by comparing it to flow rates measured in a full scale test facility where the ADMP was operated. The CFD fluid model could then be used to predict flow rates throughout the actual waste tank where the pump was to be installed, and the ability of the pump to adequately slurry the waste could be shown. All that needed to be done was to compare the local velocity of the fluid required to shear the waste into suspension to the velocities modeled throughout the waste tank. In short, this paper validates the theoretical and experimental basis for the derivation of a minimum velocity required for the flow stream to shear the waste into suspension. The final installment to this series of papers (Part IV) validates the application of the CFD model, by concluding that a nuclear waste tank is effectively cleaned to the wall throughout most of tank, using the ADMP.

Copyright © 2004 by ASME
Topics: Pumps , Slurries

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In