0

Full Content is available to subscribers

Subscribe/Learn More  >

Investigation of a Capillary Assisted Thermosyphon (CAT) for Shipboard Electronics Cooling

[+] Author Affiliations
E. H. Larsen, M. Cerza, A. N. Smith

U.S. Naval Academy, Annapolis, MD

C. Thomas Conroy

Bechtel-Bettis, Inc., West Mifflin, PA

Paper No. HT-FED2004-56483, pp. 485-494; 10 pages
doi:10.1115/HT-FED2004-56483
From:
  • ASME 2004 Heat Transfer/Fluids Engineering Summer Conference
  • Volume 4
  • Charlotte, North Carolina, USA, July 11–15, 2004
  • Conference Sponsors: Heat Transfer Division and Fluids Engineering Division
  • ISBN: 0-7918-4693-8 | eISBN: 0-7918-3740-8
  • Copyright © 2004 by ASME

abstract

As microprocessors shrink in size and increase in power dissipation levels, the current need for advanced electronics cooling techniques is paramount since power dissipation levels are rapidly exceeding the capabilities of forced air convection cooling. This paper reports an investigation of using a capillary assisted thermosyphon for the shipboard cooling of electronics components. The capillary assisted thermosyphon differs from the capillary pumped loop or loop heat pipe system in that the basic cooling loop is based on a thermosyphon. The capillary assist comes from the fact that there is a wicking structure in the flat evaporator plate, however, the wicking structure is there to spread the working fluid across the flat plate evaporator in the areas under the heat sources. This differs from a capillary pumped loop in that the wick structure does not produce a capillary pumping head from the liquid return to the vapor outlet side of the evaporator. In fact, the liquid return and vapor outlet are almost at the same pressure. The forced circulation in the thermosyphon is caused by a gravity head between the condenser cold plate and the flat plate evaporator. An experimental facility for conducting research on capillary assisted thermosyphon was developed. In order to simulate the shipboard cooling water encountered at various locations of the ocean, the heat sink temperature of the facility could be varied. A vertical flat plate, CAT evaporator was designed and tested under thermal sink temperatures of 4, 21 and 37°C. The condenser cold plate cooling water flow rate varied from 0.38 to 3 GPM. The heat input varied from 250 to 1500 W evenly spread over the area of the evaporator. The CAT flat plate evaporator performed very well under this range of heat inputs, sink temperatures, and cold plate flow rates. The main result obtained showed that as heat input increased the amount of subcooling between the evaporator vapor outlet line and liquid return line increased. This subcooling did not hinder thermal performance as measured by the internal operating temperature.

Copyright © 2004 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In