Computational Simulation of Flow in a Dissecting Aortic Aneurysm Reconstructed From CT Images

[+] Author Affiliations
Masahiro Watanabe, Teruo Matsuzawa

Japan Advanced Institute of Science and Technology

Paper No. PVP2004-3122, pp. 83-89; 7 pages
doi:10.1115/PVP2004-3122
From:
  • ASME/JSME 2004 Pressure Vessels and Piping Conference
  • Computational Technologies for Fluid/Thermal/Structural/Chemical Systems With Industrial Applications, Volume 2
  • San Diego, California, USA, July 25–29, 2004
  • Conference Sponsors: Pressure Vessels and Piping Division
  • ISBN: 0-7918-4686-5
  • Copyright © 2004 by ASME

abstract

We have simulated blood flow through the shape of dissecting aortic aneurysm reconstructed from CT images. An aortic dissection is a tear in the inner lining of the aorta, creating a space between the inner and outer layers called a false lumen. The pipe where the usual bloodstream flows is called a true lumen. The thrombus or the bloodstream exists at the exit of the false lumen. Currently, there are not flow simulations of dissecting aortic aneurysms that use the individual patient’s shape. Under these circumstances, we thought that it would be useful to examine the stress that joins the vessel walls by numerical simulation, in order to changes after the onset of the disease. To obtain accurate simulation results, we examined a method for obtaining a highly accurate dissected aortic aneurysm shape. We assumed the maximum Reynolds number for systolic pressure. The constant flow was given by the entrance boundary. The calculation scheme is a finite volume method. The Reynolds number was about 9000. The result showed that flow in the false lumen was rotational flow and lower than that in the true lumen. Flow in the true lumen was not rotational flow. In general, MRI imagery has shown that flow in the aortic arch is rotational. The magnitude of the velocity in the true lumen was about 11 times the velocity in the false lumen. Therefore, high wall shear stress was showed three areas at wall in true lumen. Both wall shear stress and pressure values were high in the re-entry portion.

Copyright © 2004 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In