0

Full Content is available to subscribers

Subscribe/Learn More  >

Modeling of Thermal Hydraulics Aspects of Combined Top and Bottom Water Reflood Experiment PARAMETER-SF2 Using SOCRAT 2.1 Code

[+] Author Affiliations
Alexander D. Vasiliev

Nuclear Safety Institute, Moscow, Russia

Paper No. IMECE2008-69043, pp. 1915-1922; 8 pages
doi:10.1115/IMECE2008-69043
From:
  • ASME 2008 International Mechanical Engineering Congress and Exposition
  • Volume 10: Heat Transfer, Fluid Flows, and Thermal Systems, Parts A, B, and C
  • Boston, Massachusetts, USA, October 31–November 6, 2008
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-4871-5 | eISBN: 978-0-7918-3840-2
  • Copyright © 2008 by ASME

abstract

The PARAMETER-SF2 test conditions simulated a severe LOCA (Loss of Coolant Accident) nuclear power plant sequence in which the overheated up to 1700÷2300K core would be reflooded from the top and the bottom in occasion of ECCS (Emergency Core Cooling System) recovery. The test was successfully conducted at the NPO “LUTCH”, Podolsk, Russia, in April 3, 2007 and was the second of two experiments to be performed in the frame of ISTC 3194 Project. PARAMETER facility of NPO “LUTCH”, Podolsk, is designed for studies of the VVER fuel assemblies behavior under conditions simulating design basis, beyond design basis and severe accidents. After the maximum cladding temperature of 1750K was reached in the bundle during PARAMETER-SF2 test, the top flooding (flow rate 40g/s) was begun and later approximately in 30 s the bottom flooding (flow rate 100g/s) was initiated. Two-phase (water and steam) flow determined the fuel assembly cooling conditions. The thermal hydraulic and SFD (Severe Fuel Damage) best estimate numerical complex SOCRAT 2.1 was used for the calculation of PARAMETER-SF2 experiment. Thermal hydraulics in PARAMETER-SF2 experiment played very important role and its adequate modeling is important for the thermal analysis. The results obtained by the complex SOCRAT 2.1 were compared with experimental data concerning different aspects of thermal hydraulics behavior including convective and radiative heat transfer in the bundle and the CCFL (counter-current flooding limitation) phenomenon during the reflood. The temperature experimental data were found to be in a good agreement with calculated results. It is indicative of the adequacy of modeling the complicated thermo-hydraulic behavior in the PARAMETER-SF2 test.

Copyright © 2008 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In