abstract

Aortic valve stenosis is a significant cause of morbidity and mortality [1]. Currently, the preferred treatment of severe aortic stenosis is aortic valve replacement, which carries a significant risk for patients with comorbidities [2]. Recently, percutaneous aortic valve (PHV) replacement represents an endovascular alternative to conventional open heart surgery without the need for sternotomy, aortotomy, or cardiopulmonary bypass [3]. However, there are significant serious adverse events associated with the percutaneous procedure, such as myocardial infarction, peripheral embolism, injury to the aorta, perivalvular leak and access site injury [3–5]. Furthermore, long-term durability and safety of these valves need to be evaluated and studied carefully. We hypothesize that the device (dys)function could be more accurately predicted if a better understanding of the biomechanical interaction between the native aortic valve/root and the PHV were available. In this study, our objective is to characterize the mechanical properties of the aortic root such that its interaction with the PHV device can be quantified.

Copyright © 2008 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In