0

Full Content is available to subscribers

Subscribe/Learn More  >

Flow Maldistribution in Multichanneled Microdevices With In-Line Manifolds

[+] Author Affiliations
J. Soman, B. Mathew, T. J. John, H. Hegab

Louisiana Tech University, Ruston, LA

Paper No. IMECE2009-11988, pp. 331-338; 8 pages
doi:10.1115/IMECE2009-11988
From:
  • ASME 2009 International Mechanical Engineering Congress and Exposition
  • Volume 9: Heat Transfer, Fluid Flows, and Thermal Systems, Parts A, B and C
  • Lake Buena Vista, Florida, USA, November 13–19, 2009
  • Conference Sponsors: ASME
  • ISBN: 978-0-7918-4382-6 | eISBN: 978-0-7918-3863-1
  • Copyright © 2009 by ASME

abstract

This paper deals with the analyses of fluid flow distribution in a microfluidic device with in-line manifolds. The analysis was performed using commercially available microfluidic simulation software called CoventorWare™. The number of channels in the microfluidic device considered for this study was kept at ten due to limitations on the number of nodes and computational time. Channels with only square profile were analyzed for flow rates varying between 1 to 60 ml/min. The length of the channels was maintained at 1.5 cm for all simulations. The fluid flow distribution characteristics for different channel widths/depths (200, 100, and 75 μm) were investigated. It was observed that the flow rate decreased from the central channels to the outer channels. The flow per channel was symmetric about the geometric centre of the microdevice. The uniformity in flow was accessed using the root mean square value of flow per channel and it decreased with decrease in channel width/depth for a specific flow rate. The difference in the flow rate through the channels increased with increase in total flow rate. Similarly, the spacing between the channels was varied (300, 200, and 100 μm) for a microdevice with channel width/depth of 100 μm and its corresponding flow characteristics were studied for flow rate ranging between 1 ml/min and 60 ml/min. Finally, the length of each manifold was varied between 2500 μm and 1000 μm for understanding the effect of manifold length on flow distribution. The standard deviation of flow per channel did not show much variation with changes in spacing and manifold length. In addition each design of the manifolds was analyzed on the basis of pressure and flow rate as well as velocity profile in each of the channels.

Copyright © 2009 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In