abstract

Premature infants are commonly treated for respiratory problems due to their underdeveloped lungs. Due to Respiratory Distress Syndrome, the infant requires mechanical ventilation or increased inspired oxygen. If the blood oxygen saturation is kept a too high of a level, the infant is at risk for retinopathy of prematurity. A safe level for the infant’s blood oxygen saturation is between 85–92%. An automatic control system would aid nurses in care of premature infants. Since each infant is different, the control system must be robust enough to achieve adequate control of the percentage of oxygen in inspired air administered to the patient. Clinical data is acquired from patient bedside monitors. A parameter estimating extended Kalman filter assuming a first order model is applied to the data to calculate a range of system gains and time constants. An error model is then created using the resulting ranges of parameters. Performance specifications are defined and a μ-synthesis controller is developed to automatically control the oxygen percentage of inspired air. The control system is analyzed using H∞ methods to determine whether robust stability and robust performance are achieved in the presence of system uncertainty described by the error model.

Copyright © 2011 by ASME
Topics: Modeling , Feedback , Oxygen

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In