0

Full Content is available to subscribers

Subscribe/Learn More  >

Polymer-Based Sensors for Dynamic Intravascular Shear Stress Analysis

[+] Author Affiliations
Lisong Ai, Hongyu Yu, Mahsa Rouhanizadeh, Wakako Takabe, Ellis Meng, E. S. Kim, Tzung Hsiai

University of Southern California, Los Angeles, CA

Paper No. BioMed2008-38097, pp. 55-57; 3 pages
doi:10.1115/BioMed2008-38097
From:
  • ASME 2008 3rd Frontiers in Biomedical Devices Conference
  • ASME 2008 3rd Frontiers in Biomedical Devices Conference
  • Irvine, California, USA, June 18–20, 2008
  • Conference Sponsors: Nanotechnology Institute
  • ISBN: 0-7918-4833-7 | eISBN: 0-7918-3823-4
  • Copyright © 2008 by ASME

abstract

This paper describes a polymer-based shear stress sensor built on catheter for in vivo measurements and potential application in atherosclerosis diagnosis. MEMS shear stress sensor with backside wire bonding has been used to address in vitro applications for micro-scale hemodynamics with high temporal and spatial resolution. However, to assess shear stress in the tortuous and dynamic arterial circulation, we had to develop a new generation of polymer- and catheter-based sensors that are both flexible and deployable. The individual sensor was packaged near the tip of a catheter for intravascular shear stress analysis. The wire bonding and electrode leads were insulated by a film of Parylene C and were connected to the external circuit along the guide-wire. The sensor was deployed through the catheter into the aorta of New Zealand White (NZW) rabbits by the femoral cut-down procedure. Based on the heat transfer principle, the device was able to detect small temperature perturbation in response to the pulsatile flow at ∼200 beats/minutes in the rabbits. The sensor was calibrated in the presence of rabbit blood flow at 37.8°C. We demonstrated the feasibility of translating a polymerbased device for dynamic intravascular measurement with a potential for clinical applications in detecting coronary artery disease and stroke.

Copyright © 2008 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In